Home / LEV Testing / Guide
LEV testing - distilleries and breweries
A distillery or brewery is a warm, humid, vapour-rich place - mashing, boiling, fermenting and distilling all put steam, heat, ethanol vapour and various process fumes into the air. Good ventilation keeps that air fit to work in, and local exhaust ventilation controls specific fumes at source. Separately, carbon dioxide from fermentation is a distinct hazard that needs managing in its own right. Here is the ventilation and fume picture, in plain terms. This is general information.
The short answer
Walk into a working distillery or brewery and you feel the environment immediately: warm, humid, and full of the smell of the process. That's steam, heat, ethanol vapour and fumes in the air - the by-products of mashing, boiling, fermenting and distilling. Keeping that air fit to work in, and controlling the specific hazards in it, is what ventilation and LEV are for. And running underneath it all is a separate, serious hazard - carbon dioxide - that needs managing in its own right. Here's the picture. This is general information. What the processes put in the air. The processes in a distillery or brewery put several things into the air. Steam and heat: mashing and boiling (in brewing), and the heating stages of distilling, produce large amounts of steam and process heat - so the environment is hot and humid. Ethanol vapour: fermentation and distillation release ethanol (alcohol) vapour into the air - the alcohol being volatile, some escapes as vapour, especially around distillation and where product is exposed. Process fumes and odours: the various stages give off characteristic fumes and strong odours. And cleaning vapours: cleaning and sanitising (a big part of brewing and distilling hygiene) adds chemical vapours. So the air is warm, humid, and carries vapours and fumes - an environment that needs managing to stay fit to work in. General ventilation: keeping the environment fit to work in. General (or dilution) ventilation is about the overall environment. Its job is to clear the steam, heat and humidity so the space doesn't become oppressively hot and humid (uncomfortable and, in extremes, a heat risk), to prevent the problems that humid air causes (condensation, which leads to wet surfaces, slip hazards, and hygiene and mould issues), and to dilute the vapours and odours across the space so they don't build up. So general ventilation keeps the whole working environment tolerable and reduces the background level of vapours - the baseline air management for a warm, humid, vapoury place. Local exhaust ventilation: capturing specific fumes at source. Where a particular task or vessel releases a specific fume or vapour that general ventilation isn't enough to control - a concentrated source at a specific point - local exhaust ventilation (LEV) captures it at source, before it spreads into the general air. So LEV is the targeted control for specific, concentrated emissions (a particular process point giving off vapour or fume), whereas general ventilation handles the diffuse, whole-space picture. The two work together: general ventilation for the overall environment, LEV for specific hot-spots. Where LEV is used to control a health exposure, it needs to actually work - so it must be maintained and, under COSHH, thoroughly examined and tested regularly (typically at least every fourteen months). Carbon dioxide: a separate, serious hazard. Running underneath all this is a distinct hazard that needs managing in its own right: carbon dioxide (CO2). Fermentation gives off large quantities of CO2, and CO2 is dangerous in a specific way that ordinary ventilation thinking can miss. It's heavier than air, so it collects in low and enclosed spaces - fermentation rooms, tanks, vessels, cellars, pits. It can displace oxygen, creating an oxygen-deficient atmosphere that can cause unconsciousness and death - and it can do so without obvious warning (you can't reliably smell or see it, and a CO2-rich, oxygen-poor space can overcome someone quickly). So CO2 is an asphyxiation hazard, particularly around fermentation and in confined or low spaces, and it needs dedicated management: awareness, ventilation of the spaces where it collects, monitoring or detection, and safe systems of work for entering enclosed spaces. This is a serious, potentially fatal hazard covered in detail in the brewing-and-distilling-lev-for-co2-and-process-fumes page - and it shouldn't be treated as just part of the general 'fumes', because it behaves differently and is deadlier. The layered picture. So a distillery or brewery has a layered air-control picture. General ventilation manages the overall warm, humid, vapoury environment (keeping it fit to work in). LEV captures specific fumes and vapours at source where needed (targeted exposure control). And dedicated CO2 management deals with the asphyxiation risk from fermentation (a separate, serious hazard). Each addresses a different part of the problem, and all three matter. Where the extraction and LEV are controlling health exposure, they need testing to confirm they work - so the protection is proven, not assumed. The takeaway. So distilleries and breweries produce steam, heat, ethanol vapour and process fumes that need good general ventilation to keep the air fit to work in, and local exhaust ventilation to control specific fumes at source. Separately, carbon dioxide from fermentation is a distinct, potentially fatal asphyxiation hazard that needs managing in its own right. Where extraction controls a health exposure, regular testing confirms it's working. This is general information - a proper assessment should cover your specific processes and spaces. This is general information.
Key points
What the processes put in the air
The processes in a distillery or brewery put several things into the air. Steam and heat: mashing and boiling (in brewing), and the heating stages of distilling, produce large amounts of steam and process heat - so the environment is hot and humid. Ethanol vapour: fermentation and distillation release ethanol (alcohol) vapour into the air, the volatile alcohol escaping as vapour especially around distillation and where product is exposed. Process fumes and odours: the various stages give off characteristic fumes and strong odours. And cleaning vapours: the cleaning and sanitising that hygiene demands adds chemical vapours.
So the air in a working distillery or brewery is warm, humid, and carries vapours and fumes - a distinctive environment that needs managing to stay fit to work in. This is the raw material the ventilation and LEV have to deal with: a lot of steam and heat (comfort and humidity), plus vapours and fumes (exposure and odour). Understanding what's in the air is the basis for the air controls that follow - general ventilation for the overall environment, LEV for specific sources. (And, importantly, one more thing the process produces - CO2 - is a hazard apart, covered later.) So what the processes put in the air - steam, heat, ethanol vapour and fume - sets the problem: a hot, humid, vapoury environment to be managed. So the air is warm, humid and full of process vapour. This is general information. This is general information.
General ventilation
General (or dilution) ventilation is about the overall environment. Its job is to clear the steam, heat and humidity so the space doesn't become oppressively hot and humid (uncomfortable to work in, and in extremes a heat risk), to prevent the problems humid air causes (condensation, leading to wet surfaces, slip hazards, and hygiene and mould issues), and to dilute the vapours and odours across the space so they don't build up to a high background level.
So general ventilation keeps the whole working environment tolerable and reduces the background level of vapours - it's the baseline air management for a warm, humid, vapoury place. In a distillery or brewery, this matters a lot: the steam and heat are considerable, so without good general ventilation the environment quickly becomes unpleasant and problematic (hot, dripping with condensation, thick with odour). General ventilation handles this diffuse, whole-space picture. What it doesn't do is control a specific, concentrated source of fume at a particular point - that's the job of LEV (next). So general ventilation - keeping the environment fit to work in - is the first air control: managing the overall warm, humid, vapoury environment. LEV complements it for specific sources. So general ventilation manages the whole-space air. This is general information. This is general information.
Local exhaust ventilation
Where a particular task or vessel releases a specific fume or vapour that general ventilation isn't enough to control - a concentrated source at a specific point - local exhaust ventilation (LEV) captures it at source, before it spreads into the general air. So LEV is the targeted control for specific, concentrated emissions (a particular process point giving off vapour or fume), whereas general ventilation handles the diffuse, whole-space picture.
The two work together: general ventilation for the overall environment, LEV for specific hot-spots where a concentrated emission needs capturing directly rather than just diluting. Whether LEV is needed, and where, depends on the specific processes and where concentrated fumes or vapours arise - which a proper assessment identifies. Importantly, where LEV is used to control a health exposure (a fume or vapour that could harm the people breathing it), it has to actually work - so it must be maintained and, under COSHH, thoroughly examined and tested regularly (typically at least every fourteen months) to confirm it's still capturing the emission. So LEV that's meant to protect health needs proving, like any LEV. So local exhaust ventilation - capturing specific fumes at source - is the second air control: targeted capture of concentrated emissions, complementing general ventilation, and needing testing where it protects health. So LEV controls the specific sources. This is general information. This is general information.
Carbon dioxide is different
Running underneath all this is a distinct hazard that needs managing in its own right, and it shouldn't be lumped in with the general 'fumes': carbon dioxide (CO2). Fermentation gives off large quantities of CO2, and CO2 is dangerous in a specific way that ordinary ventilation thinking can miss. It's heavier than air, so it collects in low and enclosed spaces - fermentation rooms, tanks, vessels, cellars, pits. It can displace oxygen, creating an oxygen-deficient atmosphere that can cause unconsciousness and death. And it can do so without obvious warning: you can't reliably smell or see it, and a CO2-rich, oxygen-poor space can overcome someone quickly.
So CO2 is an asphyxiation hazard, particularly around fermentation and in confined or low spaces, and it needs dedicated management: awareness of where it collects, ventilation of those spaces, monitoring or gas detection, and safe systems of work for entering enclosed spaces (tanks and vessels especially). This is a serious, potentially fatal hazard - and it behaves differently from the steam, heat and process vapours the general ventilation and LEV handle (it's an invisible, heavier-than-air asphyxiant, not just an odour or an irritant vapour), so it's dealt with separately and with particular care (covered in detail in the brewing-and-distilling-lev-for-co2-and-process-fumes page). So carbon dioxide is different - a separate, potentially fatal hazard - is the crucial caveat: don't treat CO2 as part of the general fumes; manage it in its own right. So CO2 is a deadly hazard needing its own management. This is general information. This is general information.
The layered picture
So a distillery or brewery has a layered air-control picture, with each layer addressing a different part of the problem. General ventilation manages the overall warm, humid, vapoury environment - keeping the space fit to work in (clearing steam and heat, controlling humidity, diluting odours). Local exhaust ventilation captures specific fumes and vapours at source where a concentrated emission needs targeted control. And dedicated CO2 management deals with the asphyxiation risk from fermentation - a separate, serious hazard needing its own measures.
All three matter, and they're not interchangeable: general ventilation won't reliably deal with a concentrated fume source (LEV's job) or a heavier-than-air CO2 pocket in a tank (dedicated CO2 management's job); LEV won't manage the whole-space humidity; and CO2 management is about a specific deadly hazard the others don't cover. So a well-run distillery or brewery manages the air on all these fronts, matched to its actual processes and spaces (which a proper assessment establishes). And where the extraction and LEV are controlling a health exposure, they need testing to confirm they work - so the protection is proven, not assumed. So the layered picture - ventilation, LEV and CO2 management together - is the summary: three complementary air controls for a warm, humid, vapour-rich, CO2-producing environment. So manage the air on every front the process demands. This is general information. This is general information.
Questions
Steam and process heat from mashing, boiling and distilling (making it hot and humid), ethanol vapour from fermentation and distillation, characteristic process fumes and odours, and chemical vapours from cleaning - so the air is warm, humid and vapour-rich, needing good ventilation; plus CO2 from fermentation, a separate hazard. A distillery or brewery puts several things into the air. Steam and heat: mashing and boiling (in brewing), and the heating stages of distilling, produce large amounts of steam and process heat, so the environment is hot and humid. Ethanol vapour: fermentation and distillation release ethanol (alcohol) vapour, the volatile alcohol escaping as vapour especially around distillation and exposed product. Process fumes and odours: the various stages give off characteristic fumes and strong odours. And cleaning vapours: the cleaning and sanitising that hygiene demands adds chemical vapours. So the air is warm, humid, and carries vapours and fumes - a distinctive environment needing management to stay fit to work in, through general ventilation (for the whole space) and LEV (for specific sources). Separately, fermentation produces large quantities of carbon dioxide (CO2), which is a distinct and serious hazard managed in its own right - not just part of the general fumes. So it's steam, heat, ethanol vapour and fume, plus CO2 as a separate hazard. So warm, humid air full of steam, vapour and fume, plus CO2. This is general information. This is general information.
General ventilation manages the whole-space environment - clearing steam, heat and humidity and diluting odours to keep the space fit to work in; LEV captures a specific, concentrated fume or vapour at source where general ventilation isn't enough; they work together, general for the overall air, LEV for hot-spots. The difference is scale and target. General (dilution) ventilation manages the overall environment: it clears the steam, heat and humidity so the space doesn't become oppressively hot and humid (or condensation-ridden, causing slips and hygiene problems), and dilutes vapours and odours across the whole space so they don't build up. So it handles the diffuse, whole-space picture - the baseline air management for a warm, humid, vapoury place. Local exhaust ventilation (LEV) is targeted: where a particular task or vessel releases a specific, concentrated fume or vapour that general ventilation isn't enough to control, LEV captures it at source before it spreads. So LEV deals with specific hot-spots - a concentrated emission at a particular point. The two work together: general ventilation for the overall environment, LEV for specific sources. They're not interchangeable - general ventilation won't reliably control a concentrated fume source, and LEV won't manage whole-space humidity. Where LEV controls a health exposure, it needs testing (typically at least every 14 months) to confirm it works. So general ventilation is for the whole space; LEV is for specific sources. So one manages the whole air, the other captures specific fumes. This is general information. This is general information.
Because CO2 behaves differently and is deadlier - it's heavier than air, collects in low and enclosed spaces, and displaces oxygen to fatal levels without obvious warning; so it's an asphyxiation hazard needing its own management (ventilation of low spaces, detection, safe entry systems), not just lumped in with general fumes. Carbon dioxide is treated separately from the other fumes because it behaves differently and is deadlier, so ordinary ventilation thinking can miss it. Fermentation gives off large quantities of CO2, and CO2 is dangerous in a specific way: it's heavier than air, so it collects in low and enclosed spaces (fermentation rooms, tanks, vessels, cellars, pits) rather than dispersing upward; it displaces oxygen, creating an oxygen-deficient atmosphere that can cause unconsciousness and death; and it does so without obvious warning - you can't reliably smell or see it, and a CO2-rich, oxygen-poor space can overcome someone quickly. So CO2 is an asphyxiation hazard, particularly around fermentation and in confined or low spaces, and it needs dedicated management: awareness of where it collects, ventilation of those spaces, monitoring or gas detection, and safe systems of work for entering enclosed spaces like tanks. Because it's an invisible, heavier-than-air asphyxiant - not just an odour or irritant vapour - it can't be lumped in with the general fumes that ventilation and LEV handle; it needs its own, careful management. This is covered in the brewing-and-distilling-lev-for-co2-and-process-fumes page. So it's a distinct, potentially fatal hazard that behaves unlike other fumes. So because it's a heavier-than-air, invisible, deadly asphyxiant. This is general information. This is general information.
Where LEV is used to control a health exposure - capturing a specific fume or vapour that could harm the people breathing it - yes, it must be maintained and thoroughly examined and tested regularly (typically at least every 14 months) under COSHH, to confirm it still captures the emission; a proper assessment identifies where LEV is needed. Where a brewery or distillery uses LEV to control a health exposure - capturing a specific fume or vapour that could harm the people breathing it - then yes, that LEV needs testing. Under COSHH, LEV used to control exposure to a hazardous substance must be maintained and thoroughly examined and tested regularly (typically at least every fourteen months for most systems), to confirm it's still capturing the emission as it should. This applies to LEV controlling a genuine health exposure, just as in any workplace. Whether, and where, LEV is needed in a particular brewery or distillery depends on its specific processes and where concentrated fumes or vapours arise that general ventilation isn't enough for - which a proper assessment identifies. General ventilation (managing the overall environment) isn't the same as LEV and isn't subject to the same statutory test, but where LEV is installed for exposure control, it needs proving. And the CO2 hazard is managed through its own measures (ventilation, detection, safe entry), separate from LEV testing. So where LEV controls a health exposure, it needs regular testing; a proper assessment establishes where that applies. So yes - any LEV controlling a health exposure needs testing. So yes, where LEV controls exposure - test it regularly. This is general information. This is general information.
Because the steam and humidity cause condensation, leading to wet surfaces and slip hazards, and hygiene and mould problems - so clearing the humidity with good general ventilation is about safety and hygiene, not just comfort; it also helps keep the background level of vapours and odours down. The humid environment matters beyond comfort because the steam and humidity cause practical problems that affect safety and hygiene. When a space is full of steam and humidity (as a brewery or distillery is, from mashing, boiling and distilling), the moisture condenses on cooler surfaces - walls, ceilings, equipment, floors. That condensation leads to wet surfaces (a slip hazard for people working there), and to hygiene and mould problems (persistent damp encouraging mould and making surfaces harder to keep clean, which matters in a food-and-drink production setting). So clearing the humidity with good general ventilation isn't just about making the space comfortable to work in (though that matters too, and extreme heat and humidity can be a heat risk) - it's about preventing wet, slippery surfaces and damp-related hygiene issues. Good general ventilation also helps keep the background level of vapours and odours down. So the humidity is a genuine operational and safety issue, not just an comfort one - which is part of why good ventilation matters in these environments. So because humidity causes slips, damp and hygiene problems, not just discomfort. So because condensation brings slip and hygiene risks. This is general information. This is general information.
In three complementary layers: general ventilation manages the overall warm, humid, vapoury environment; LEV captures specific concentrated fumes at source; and dedicated CO2 management handles the asphyxiation risk from fermentation - each covers a different part of the problem, and all three matter, matched to the actual processes. The air controls in a distillery or brewery fit together in three complementary layers, each addressing a different part of the problem. General ventilation manages the overall warm, humid, vapoury environment - clearing steam and heat, controlling humidity (and the condensation, slips and hygiene issues it causes), and diluting odours, to keep the space fit to work in. Local exhaust ventilation (LEV) captures specific fumes and vapours at source, where a concentrated emission at a particular point needs targeted control rather than just whole-space dilution. And dedicated CO2 management deals with the asphyxiation risk from fermentation - a separate, serious, potentially fatal hazard needing its own measures (ventilation of low spaces, detection, safe entry to enclosed spaces). All three matter and aren't interchangeable: general ventilation won't handle a concentrated fume source or a CO2 pocket in a tank; LEV won't manage whole-space humidity; CO2 management addresses a specific deadly hazard the others don't cover. So a well-run site manages the air on all these fronts, matched to its actual processes and spaces, with the LEV tested where it controls a health exposure. So they fit as three layers - general ventilation, LEV, and CO2 management - each for a different part of the air. So as three complementary layers, all needed. This is general information. This is general information.
Distilleries and breweries need general ventilation for the warm, humid, vapoury environment and LEV for specific fumes - plus separate CO2 management for the asphyxiation risk; where LEV controls a health exposure, we thoroughly examine and test it to confirm it works, so the protection is proven, not assumed. Ask us to test your LEV. This is general information.