Extraction cleaning - myths
Some comfortable beliefs about extract cleaning are wrong in ways that cost money - in fire risk, in failed claims, in cleaning done badly. Here are the common myths, and what is actually true.
The short answer
The myths that cost kitchens money are the reassuring ones - that cleaning the canopy is enough, that the filters do the real job, that once a year covers any kitchen, that a clean-looking system is a clean system, and that any cleaner will do. Each feels sensible and each is wrong in a way that leaves fire risk in place or a claim exposed. Replacing them with the truth is where the saving is.
Myth one
The most expensive myth is that cleaning the visible canopy and filters cleans the system. It does not. The grease that sets the fire risk collects in the concealed ductwork, the risers and the extract fan - none of which a canopy clean touches. A gleaming canopy over a grease-packed duct run is a kitchen that looks safe and is not.
The truth is that TR19 Grease is a whole-system standard: the concealed run has to be cleaned and measured too. Believing the canopy is enough leaves the actual hazard untouched and produces a certificate that cannot honestly cover the system - which is exactly the gap an insurer looks for after a fire.
Myths two and three
A related myth is that the filters catch the grease, so the ductwork stays clean. Filters catch some grease, but plenty passes through into the ductwork beyond - which is why the concealed run needs cleaning regardless of how diligently the filters are changed. Relying on the filters to keep the system clean is relying on them to do a job they were never designed to finish.
The other frequent myth is that cleaning once a year covers any kitchen. Frequency is risk-based, not fixed: a heavy-frying kitchen may need cleaning every three months, and an annual clean on such a system lets grease build to a dangerous level between visits. A blanket once-a-year rule under-cleans the busy kitchens that need it most and is exactly the kind of assumption that lapses a compliance interval without anyone noticing.
Myth four
It is tempting to judge a clean by how the system looks afterwards - bright canopy, shiny filters - but appearance is not the standard. TR19 Grease is measured: grease deposit is assessed by thickness, before and after, because the eye cannot tell a compliant clean from a superficial one. A system can look spotless at the visible points and still carry dangerous grease where it matters.
Believing that clean-looking equals clean leads kitchens to accept superficial cleans and thin certificates that prove nothing. The truth is that only measurement tells you the system is genuinely below the cleaning threshold - which is why a proper clean comes with readings, and why a certificate with none is not evidence of anything.
Myth five
The final costly myth is that extract cleaning is a general cleaning job any contractor can do, so the cheapest will do fine. Cleaning to TR19 Grease is a specialist, measured discipline - reaching the whole concealed system, fitting access where needed, taking grease readings, and producing a verifiable certificate. A general cleaner without the equipment, access provision, qualifications or measurement cannot deliver that, whatever the invoice says.
The cost of this myth is a clean that looks done but is not compliant, from a contractor who cannot evidence it - leaving the fire risk and the insurance exposure in place. The truth is that the contractor matters: a registered, qualified one whose work generates a verifiable certificate is doing a fundamentally different job from a general cleaner with a cloth.
The takeaway
Every one of these myths is comfortable because it makes extract cleaning sound simpler and cheaper than it is - the canopy, the filters, once a year, looks clean, any cleaner. And every one costs money in the way that matters most: fire risk left in place, and a claim left exposed. The reassurance is the expensive part.
The truth is less comfortable but cheaper in the end: the whole system, cleaned at a risk-based frequency, measured, and certificated by a competent contractor. That is what actually controls the risk and protects the cover - and a kitchen that swaps the myths for that reality is buying genuine protection instead of a false sense of it.
Questions
No - it is a myth that costs money. The grease that sets the fire risk is in the concealed ductwork, risers and fan, none of which a canopy clean touches. TR19 Grease requires the whole system cleaned and measured.
No. Filters catch some grease, but plenty passes through into the ductwork beyond, which needs cleaning regardless. Relying on filters to keep the system clean asks them to do a job they were not designed to finish.
No. Frequency is risk-based - a heavy-frying kitchen may need cleaning every three months. An annual clean on such a system lets grease build to a dangerous level and can lapse a compliance interval unnoticed.
Not necessarily. TR19 Grease is measured by grease deposit thickness, because the eye cannot tell a compliant clean from a superficial one. Only readings confirm the system is genuinely below the cleaning threshold.
No. Cleaning to TR19 Grease is a specialist, measured discipline needing access provision, equipment, qualifications and verifiable certification. A general cleaner cannot deliver or evidence that, leaving the risk and exposure in place.
The whole system, cleaned at a risk-based frequency, measured, and certificated by a competent contractor. That is what controls the fire risk and protects the insurance cover - and it is cheaper than the myths in the end.
We clean the whole system, measure it and certificate it - the reality behind the reassuring myths, and the protection they leave out.