Phoenix Cleaning Company Call 07961 915018
LEV Testing in Bramhall

LEV Testing · Bramhall

LEV testing in Bramhall.

From the dental laboratory to the engineering and finishing units, Bramhall workplaces raise fume, mist and dust that the law says must be controlled - and the control proven by a thorough examination and test.

HSG258 examinationMeasured airflow readingsReport & labelFully insured

Where fume and dust control sits in Bramhall

Bramhall carries a run of trade units on the Stockport edge, and a dental laboratory among them casts and trims gypsum models, cures acrylic dentures and grinds cobalt-chrome frameworks. Where a lab trims gypsum, cures acrylic and grinds metal the dust and vapour are real - the model-trimming throws off a gypsum dust, the acrylic curing a methyl-methacrylate vapour and the framework-grinding a cobalt-chrome dust that scars the lungs - and the units' engineering and finishing shops add weld fume, oil mist and grinding dust, all things a worker should not breathe.

Local exhaust ventilation is what captures it at source, and the law does not take the control on trust. Under COSHH the model-trimming dust extraction, the acrylic-vapour capture and the framework-grinding extraction have to be thoroughly examined and tested at least every 14 months, measured against how they are used, not just switched on and assumed to work.

The Bramhall workplaces that need an LEV test

01

Precision engineering

CNC and manual machining raises oil mist and metal dust at the enclosure and bench that has to be captured at source.

02

Food and drink production

Flour, powders and steam need capture at the mixing and process points, from bakeries to production kitchens.

03

Woodworking and joinery

Saws, sanders and routers throw fine wood dust that has to be drawn off at the tool and the bench.

04

Welding and fabrication

Weld fume and grinding dust need capture at the arm and booth, wherever steel is fabricated.

05

Vehicle body and paint

Bodyshop spray booths and prep bays carry paint mist and solvent vapour that the extraction has to hold and clear.

06

Laboratory and clinical

Fume cupboards, safety cabinets and dental and salon extraction all count as LEV and all fall due on the same clock.

What we have tested around Bramhall

Real jobs, described by sector and area - never by a client's name.

Dental laboratory · Bramhall area

A gypsum-dust and acrylic-vapour test

At a dental laboratory on a Stockport trade unit near Bramhall, trimming gypsum and grinding cobalt-chrome, the extraction over the model-trimming bench, the acrylic bench and the grinding station had lost capture and gypsum dust, monomer vapour and metal dust were building around the technicians. We measured capture at the trimming bench, the acrylic bench and the grinding station, checked the ducting and the filter, and found a fan below duty dragging the run. We set out the remedial action, and re-tested to confirm the control before certifying.

Engineering unit · Bramhall area

A weld-fume and mist extraction test

At an engineering unit on a Stockport trade unit near Bramhall, the weld-fume arms and mist extraction over the machining had lost capture and the shop was hazing by mid-shift. We measured capture and face velocities at each point, checked the ducting and the filters, and reported what needed putting right so it held its spec on a re-test.

What a thorough examination and test measures in Bramhall

01

Visual and structural

Condition of hoods, ducting, filters and fan - the damage, blockage and wear that quietly drops performance.

02

Quantitative performance

Measured capture and face velocities at the working points, plus transport velocity and static pressure through the system.

03

Benchmark to design

The readings assessed against how the LEV should perform to actually control the exposure - not just whether the fan turns.

04

Air sampling, where needed

Where the process warrants it, sampling to confirm the control is keeping the substance out of the breathing zone.

LEV TESTINGBramhallHSG258

Fourteen months, and whose name is on it

The point of a thorough examination and test is to prove the extraction still controls the exposure - so we measure it, we do not eyeball it. Condition, capture and face velocities, transport velocity and static pressure are checked against the design intent under HSG258, and the result is written up and labelled on the plant.

We test to the HSE's guidance, HSG258, and the job ends in a report and a label on the plant: what was measured, what passed, what needs putting right, and the date the next test falls due.

  • The system examined end to end - hood to discharge
  • Capture and face velocities measured at source
  • Transport velocity and static pressure recorded
  • A report, a verdict and a label with the next-due date

Examine, measure, report, label

1

Inspect

We examine the condition of the hoods, ducting, filter and fan and how each is meant to control its process.

2

Test

We measure capture and face velocities, transport velocity and static pressure at every key point.

3

Assess

The readings are judged against the design benchmark under HSG258, with a clear pass or fail on control.

4

Certify

The plant is labelled and you get the report and next-due date for your COSHH records.

Frequently asked questions

How often does LEV have to be tested?

At least every 14 months under COSHH Regulation 9 - and sooner for certain higher-risk processes. We set the right interval for what you run and put the next-due date on the label and the report.

What do we get at the end?

A thorough-examination-and-test report against HSG258, a pass/fail on each point with any remedials listed, and a dated label on the plant showing when the next test falls due.

What if a point fails?

We set out exactly what failed and why - often a single reading such as static pressure or capture velocity - so it can be put right, and we re-test to confirm the control before certifying.

Do you cover the the surrounding Stockport trade units and the wider town?

Yes - the the surrounding Stockport trade units and the town's units, and across Bramhall and the wider Greater Manchester.

Do you only test engineering extraction?

No - any LEV: welding fume arms, wood and grain dust systems, spray booths, mist extraction, fume cupboards, and dental and salon extraction all fall under the same duty and the same clock.

LEV testing in Bramhall

In and around Bramhall

Bramhall runs a dental laboratory and a run of engineering units on the Stockport trade units, trimming gypsum, curing acrylic, grinding cobalt-chrome, welding and machining - raising gypsum dust, monomer vapour, metal dust and weld fume. Every one carries a duty to control what its work throws off - and to prove it with a measured test.

20+ years of experience

We have carried out LEV thorough examination and testing to HSG258 since 2001, across Greater Manchester and the UK. From a machine shop to a joinery, a spray booth or a lab fume cupboard, the job ends the same way: measured readings, a clear verdict, and a label whose next-due date you can rely on.

Book your Bramhall LEV thorough examination

Tell us what you run and we will examine, measure, report and label it to HSG258 - across Greater Manchester.