LEV testing in Cinderford.

From the engineering units to the joinery and vehicle shops, Cinderford workplaces raise fume, mist and dust that the law says must be controlled - and the control proven by a thorough examination and test.

HSG258 examinationMeasured airflow readingsReport & labelFully insured

Where fume and dust control sits in Cinderford

The workshops of Cinderford are where the engineering and fabrication units weld and machine, the joinery and timber shops cut and sand, and the vehicle shops grind and refinish. The arc and the grinder raise weld fume and metal dust, and the joinery and spray work add wood dust, oil mist and paint mist, all of which a worker should be kept from breathing.

It is local exhaust ventilation that captures the fume and dust at source - and the control has to be proven, not assumed. Under COSHH the weld-fume arms, wood-dust extraction and spray and mist extraction must be thoroughly examined and tested at least every 14 months, measured against how they are actually run.

The Cinderford workplaces that need an LEV test

01

Precision engineering

CNC and manual machining raises oil mist and metal dust at the enclosure and bench that has to be captured at source.

02

Food and drink production

Flour, powders and steam need capture at the mixing and process points, from bakeries to production kitchens.

03

Woodworking and joinery

Saws, sanders and routers throw fine wood dust that has to be drawn off at the tool and the bench.

04

Welding and fabrication

Weld fume and grinding dust need capture at the arm and booth, wherever steel is fabricated.

05

Vehicle body and paint

Bodyshop spray booths and prep bays carry paint mist and solvent vapour that the extraction has to hold and clear.

06

Laboratory and clinical

Fume cupboards, safety cabinets and dental and salon extraction all count as LEV and all fall due on the same clock.

Typical LEV tests around Cinderford

Typical jobs we handle, by sector and area - representative of the work we do, not named clients.

Engineering unit - Forest Vale, Cinderford

A weld-fume and grinding-dust test

At an engineering unit on the Forest Vale estate in Cinderford, welding, grinding and fabricating, the extraction had lost capture and the shop was hazing by mid-shift. We measured capture and face velocities at each point, checked the ducting and filters, and traced it to a fan running below duty. We detailed the remedials and re-tested to confirm the LEV met HSG258 before labelling it.

Joinery unit - Cinderford

A wood-dust extraction test

At a joinery unit near Cinderford, running the saws, planers and sander, the hoods were no longer holding the wood dust and the shop had gone hazy. We took capture readings at every hood, inspected the ductwork and filters, and found a blocked filter bank throttling the system. We set out the fix, re-tested to confirm capture was back to spec, and certified to HSG258 with a dated label.

What a thorough examination and test measures in Cinderford

01

Visual and structural

Condition of hoods, ducting, filters and fan - the damage, blockage and wear that quietly drops performance.

02

Quantitative performance

Measured capture and face velocities at the working points, plus transport velocity and static pressure through the system.

03

Benchmark to design

The readings assessed against how the LEV should perform to actually control the exposure - not just whether the fan turns.

04

Air sampling, where needed

Where the process warrants it, sampling to confirm the control is keeping the substance out of the breathing zone.

LEV TESTINGCinderford

Fourteen months, and whose name is on it

A thorough examination and test under COSHH is a real assessment, not a rubber stamp. It is a structured examination of the system's condition, measurement of its actual performance, and an assessment of those readings against how the system should perform to control the exposure. It follows the HSE's guidance, HSG258, and ends in a report and a label.

We test to the HSE's guidance, HSG258, and the job ends in a report and a label on the plant: what was measured, what passed, what needs putting right, and the date the next test falls due.

  • Visual and structural examination of hoods, ducting, filter and fan
  • Measured airflow, capture and face velocities at the working points
  • Static pressure and duct transport velocity readings recorded
  • Report against the benchmark, with a label and the next-due date

Examine, measure, report, label

1

Inspect

We examine the condition of the hoods, ducting, filter and fan and how each is meant to control its process.

2

Test

We measure capture and face velocities, transport velocity and static pressure at every key point.

3

Assess

The readings are judged against the design benchmark under HSG258, with a clear pass or fail on control.

4

Certify

The plant is labelled and you get the report and next-due date for your COSHH records.

Frequently asked questions

How often does LEV have to be tested?

At least every 14 months under COSHH Regulation 9 - and sooner for certain higher-risk processes. We set the right interval for what you run and put the next-due date on the label and the report.

What do we get at the end?

A thorough-examination-and-test report against HSG258, a pass/fail on each point with any remedials listed, and a dated label on the plant showing when the next test falls due.

What if a point fails?

We set out exactly what failed and why - often a single reading such as static pressure or capture velocity - so it can be put right, and we re-test to confirm the control before certifying.

Do you cover Cinderford and the wider area?

Yes - the Cinderford workshops and units, and across Cinderford and the wider Gloucestershire.

Do you only test engineering extraction?

No - any LEV: welding fume arms, wood and grain dust systems, spray booths, mist extraction, fume cupboards, and dental and salon extraction all fall under the same duty and the same clock.

LEV testing in Cinderford

In and around Cinderford

Around Cinderford the metal, timber and vehicle work raises weld fume, metal and wood dust, oil mist and paint mist. Every workshop that produces it carries the same duty: capture it at source, and prove with a measured test that the capture works.

20+ years of experience

We have carried out LEV thorough examination and testing to HSG258 since 2001, across Gloucestershire and the UK. From a machine shop to a joinery, a spray booth or a lab fume cupboard, the job ends the same way: measured readings, a clear verdict, and a label whose next-due date you can rely on.

Book your Cinderford LEV thorough examination

Tell us what you run and we will examine, measure, report and label it to HSG258 - across Gloucestershire.