LEV testing in Crosby.

Toward the Seaforth docks the engineering, logistics and marine trades raise fume, mist and dust the law says must be controlled. We examine and test local exhaust ventilation to HSG258 and certify it.

HSG258 examinationMeasured airflow readingsReport & labelFully insured

Where fume and dust control sits in Crosby

Crosby runs down to the working riverside at Seaforth, where the docks, the logistics units and the engineering and marine trades sit within reach of the town. The fabrication shops, the vehicle trades and the joineries around Crosby and the port all raise fume, mist or dust, and each depends on local exhaust ventilation that captures it at source.

An LEV system slips out of tune unseen, its filters loading and its fan tiring until a hood no longer controls the exposure. We carry out thorough examination and testing to HSG258 across Crosby - measured capture and face velocities at the working points, a verdict against the system's intended performance, and a label with a next-due date you can rely on.

The Crosby workplaces that need an LEV test

01

Precision engineering

CNC and manual machining raises oil mist and metal dust at the enclosure and bench that has to be captured at source.

02

Food and drink production

Flour, powders and steam need capture at the mixing and process points, from bakeries to production kitchens.

03

Woodworking and joinery

Saws, sanders and routers throw fine wood dust that has to be drawn off at the tool and the bench.

04

Welding and fabrication

Weld fume and grinding dust need capture at the arm and booth, wherever steel is fabricated.

05

Vehicle body and paint

Bodyshop spray booths and prep bays carry paint mist and solvent vapour that the extraction has to hold and clear.

06

Laboratory and clinical

Fume cupboards, safety cabinets and dental and salon extraction all count as LEV and all fall due on the same clock.

What we have tested around Crosby

Real jobs, described by sector and area - never by a client's name.

Fabrication unit · Seaforth

A weld-fume test

At a fabrication unit toward Seaforth, the weld-fume extraction over the bays needed its thorough examination. We measured capture at each arm and the transport velocity through the system, flagged a slow arm, and re-tested after the fix before certifying.

Bodyshop · Crosby

A spray-booth examination

A Crosby bodyshop's spray booth needed testing. We measured the booth airflow and capture, checked the filters, set out the corrections and labelled the plant with the readings and next-due date.

What a thorough examination and test measures in Crosby

01

Visual and structural

Condition of hoods, ducting, filters and fan - the damage, blockage and wear that quietly drops performance.

02

Quantitative performance

Measured capture and face velocities at the working points, plus transport velocity and static pressure through the system.

03

Benchmark to design

The readings assessed against how the LEV should perform to actually control the exposure - not just whether the fan turns.

04

Air sampling, where needed

Where the process warrants it, sampling to confirm the control is keeping the substance out of the breathing zone.

LEV TESTINGCrosby

Fourteen months, and whose name is on it

The point of a thorough examination and test is to prove the extraction still controls the exposure - so we measure it, we do not eyeball it. Condition, capture and face velocities, transport velocity and static pressure are checked against the design intent under HSG258, and the result is written up and labelled on the plant.

We test to the HSE's guidance, HSG258, and the job ends in a report and a label on the plant: what was measured, what passed, what needs putting right, and the date the next test falls due.

  • The system examined end to end - hood to discharge
  • Capture and face velocities measured at source
  • Transport velocity and static pressure recorded
  • A report, a verdict and a label with the next-due date

Examine, measure, report, label

1

Inspect

We examine the condition of the hoods, ducting, filter and fan and how each is meant to control its process.

2

Test

We measure capture and face velocities, transport velocity and static pressure at every key point.

3

Assess

The readings are judged against the design benchmark under HSG258, with a clear pass or fail on control.

4

Certify

The plant is labelled and you get the report and next-due date for your COSHH records.

Frequently asked questions

How often does LEV need testing?

At least every 14 months for most systems, more often for higher-risk work. We set the interval to the process and label it on the plant.

What does the test measure?

Condition of hoods, ducts, filters and fan; measured capture and face velocities; transport velocity and static pressure - all against how the LEV should perform to control the exposure.

What if something fails?

We set out exactly what failed - often one reading - so it can be put right, and re-test to confirm control before certifying.

Do you cover the Seaforth and dockside units?

Yes - the riverside and estate units across Crosby, and the wider Merseyside.

Do you only test welding extraction?

No - welding fume, metal and wood dust, spray booths, mist extraction, fume cupboards and salon and dental extraction all fall under the same duty.

LEV testing in Crosby

In and around Crosby

The Seaforth riverside keeps Crosby's engineering, logistics and marine trades working, units welding, machining and fabricating within reach of the docks - each raising a fume or dust its LEV has to draw off at source. We test to HSG258 so those workshops can prove their extraction controls what their people breathe.

20+ years of experience

We have carried out LEV thorough examination and testing to HSG258 since 2001, across Merseyside and the UK. From a machine shop to a joinery, a spray booth or a lab fume cupboard, the job ends the same way: measured readings, a clear verdict, and a label whose next-due date you can rely on.

Book your Crosby LEV thorough examination

Tell us what you run and we will examine, measure, report and label it to HSG258 - across Merseyside.