Phoenix Cleaning Company Call 07961 915018
LEV Testing in Cross Hands

LEV Testing · Cross Hands

LEV testing in Cross Hands.

The workshops of Cross Hands - engineering, timber and vehicle alike - raise the fume, mist and dust that COSHH says must be captured and the capture proven by a thorough examination and test.

HSG258 examinationMeasured airflow readingsReport & labelFully insured

Where fume and dust control sits in Cross Hands

Around Cross Hands the engineering and fabrication units weld and machine, the joinery and timber shops cut and sand, and the vehicle and distribution workshops grind and refinish. Where a workshop welds and grinds the fume and dust are real - the arc and the grinder throw off weld fume and metal dust - and the joinery and refinishing units add wood dust, oil mist and paint mist, all things a worker should not breathe.

It is local exhaust ventilation that captures the fume and dust at source - and the control has to be proven, not assumed. Under COSHH the weld-fume arms, wood-dust extraction and spray and mist extraction must be thoroughly examined and tested at least every 14 months, measured against how they are actually run.

The Cross Hands workplaces that need an LEV test

01

Precision engineering

CNC and manual machining raises oil mist and metal dust at the enclosure and bench that has to be captured at source.

02

Food and drink production

Flour, powders and steam need capture at the mixing and process points, from bakeries to production kitchens.

03

Woodworking and joinery

Saws, sanders and routers throw fine wood dust that has to be drawn off at the tool and the bench.

04

Welding and fabrication

Weld fume and grinding dust need capture at the arm and booth, wherever steel is fabricated.

05

Vehicle body and paint

Bodyshop spray booths and prep bays carry paint mist and solvent vapour that the extraction has to hold and clear.

06

Laboratory and clinical

Fume cupboards, safety cabinets and dental and salon extraction all count as LEV and all fall due on the same clock.

Typical LEV tests around Cross Hands

Typical jobs we handle, by sector and area - representative of the work we do, not named clients.

Fabrication unit - Cross Hands Business Park

A weld-fume and grinding-dust test

At a fabrication unit on the Cross Hands Business Park, welding, grinding and fabricating, the capture at the hoods had fallen off and a haze hung over the benches. We took capture readings at every hood, inspected the ductwork and filters, and found a blocked filter bank throttling the system. We listed the remedials, and re-tested to prove the control once put right, then certified to HSG258.

Vehicle workshop - Cross Hands

A spray-mist extraction test

At a vehicle workshop at Cross Hands, spraying and finishing, the capture at the hoods had fallen off and a haze hung over the benches. We measured face velocities and static pressure, checked the run, and found undersized ducting and a worn fan. We listed the remedials, and re-tested to prove the control once put right, then certified to HSG258.

What a thorough examination and test measures in Cross Hands

01

Visual and structural

Condition of hoods, ducting, filters and fan - the damage, blockage and wear that quietly drops performance.

02

Quantitative performance

Measured capture and face velocities at the working points, plus transport velocity and static pressure through the system.

03

Benchmark to design

The readings assessed against how the LEV should perform to actually control the exposure - not just whether the fan turns.

04

Air sampling, where needed

Where the process warrants it, sampling to confirm the control is keeping the substance out of the breathing zone.

LEV TESTINGCross Hands

Fourteen months, and whose name is on it

A thorough examination and test under COSHH is a real assessment, not a rubber stamp. It is a structured examination of the system's condition, measurement of its actual performance, and an assessment of those readings against how the system should perform to control the exposure. It follows the HSE's guidance, HSG258, and ends in a report and a label.

We test to the HSE's guidance, HSG258, and the job ends in a report and a label on the plant: what was measured, what passed, what needs putting right, and the date the next test falls due.

  • Visual and structural examination of hoods, ducting, filter and fan
  • Measured airflow, capture and face velocities at the working points
  • Static pressure and duct transport velocity readings recorded
  • Report against the benchmark, with a label and the next-due date

Examine, measure, report, label

1

Inspect

We examine the hoods, ducting, filter and fan and identify how each is meant to control its process.

2

Take readings

We record capture and face velocities, transport velocity and static pressure at every key point.

3

Judge

The readings are assessed against the design intent under HSG258, with a clear verdict on control.

4

Label up

The plant is labelled with the result and next-due date, and you get the report for the COSHH file.

Frequently asked questions

How often does LEV have to be tested?

COSHH Regulation 9 sets a maximum of 14 months between tests, and some higher-risk processes need it sooner. We set the interval to match what you run and record the next-due date on the label and the report.

What do we get at the end?

A thorough-examination-and-test report against HSG258, a pass/fail on each point with any remedials listed, and a dated label on the plant showing when the next test falls due.

What if a point fails?

We set out exactly what failed and why - often a single reading such as static pressure or capture velocity - so it can be put right, and we re-test to confirm the control before certifying.

Do you cover Cross Hands and the wider area?

Yes - the Cross Hands workshops and units, and across Cross Hands and the wider Carmarthenshire.

Do you only test engineering extraction?

No - any LEV: welding fume arms, wood and grain dust systems, spray booths, mist extraction, fume cupboards, and dental and salon extraction all fall under the same duty and the same clock.

LEV testing in Cross Hands

In and around Cross Hands

Cross Hands works its metal, timber and vehicles, welding and grinding, sawing and sanding, and refinishing - raising weld fume, metal and wood dust, oil mist and paint mist. Every one carries a duty to control what its work throws off - and to prove it with a measured test.

20+ years of experience

We have carried out LEV thorough examination and testing to HSG258 since 2001, across South Wales and the UK. From a machine shop to a joinery, a spray booth or a lab fume cupboard, the job ends the same way: measured readings, a clear verdict, and a label whose next-due date you can rely on.

Book your Cross Hands LEV thorough examination

Tell us what you run and we will examine, measure, report and label it to HSG258 - across South Wales.