LEV Testing in Hawarden

LEV Testing · Hawarden

LEV testing in Hawarden.

The aerospace, engineering and vehicle units at Broughton and Hawarden Airport weld, machine, rivet and finish, raising fume, mist and dust the law says must be controlled. We examine and test local exhaust ventilation to HSG258 and certify it.

HSG258 examinationMeasured airflow readingsReport & labelFully insured

Where fume and dust control sits in Hawarden

Hawarden sits beside one of Wales's biggest manufacturing sites, the Airbus wing works at Broughton and the engineering and support units around Hawarden Airport. Their welding and riveting bays, composite and machining benches, spray booths and grinding lines all raise something their local exhaust ventilation has to capture at source.

LEV works hard and quietly loses its edge - filters load, ducts fur, a fan tires - until a hood stops holding the exposure. We carry out thorough examination and testing to HSG258 across Hawarden: measured capture and face velocities at the working points, a judgement against how the system was meant to perform, and a label carrying a next-due date you can trust.

The Hawarden workplaces that need an LEV test

01

Precision engineering

CNC and manual machining raises oil mist and metal dust at the enclosure and bench that has to be captured at source.

02

Food and drink production

Flour, powders and steam need capture at the mixing and process points, from bakeries to production kitchens.

03

Woodworking and joinery

Saws, sanders and routers throw fine wood dust that has to be drawn off at the tool and the bench.

04

Welding and fabrication

Weld fume and grinding dust need capture at the arm and booth, wherever steel is fabricated.

05

Vehicle body and paint

Bodyshop spray booths and prep bays carry paint mist and solvent vapour that the extraction has to hold and clear.

06

Laboratory and clinical

Fume cupboards, safety cabinets and dental and salon extraction all count as LEV and all fall due on the same clock.

What we have tested around Hawarden

Real jobs, described by sector and area - never by a client's name.

Aerospace-support unit · Broughton

A machining and grinding LEV test

At a Broughton aerospace-support unit the machining and grinding extraction needed examining. We measured capture at each bench and the transport velocity through the ducting, found one branch starved, set the fix, and re-tested before certifying.

Engineering unit · Hawarden Airport

A weld-fume examination

An engineering unit at Hawarden Airport needed its weld-fume extraction testing. We measured capture at each arm and the transport velocity, and labelled the plant with the readings and next-due date.

What a thorough examination and test measures in Hawarden

01

Visual and structural

Condition of hoods, ducting, filters and fan - the damage, blockage and wear that quietly drops performance.

02

Quantitative performance

Measured capture and face velocities at the working points, plus transport velocity and static pressure through the system.

03

Benchmark to design

The readings assessed against how the LEV should perform to actually control the exposure - not just whether the fan turns.

04

Air sampling, where needed

Where the process warrants it, sampling to confirm the control is keeping the substance out of the breathing zone.

LEV TESTINGHawarden

Fourteen months, and whose name is on it

The point of a thorough examination and test is to prove the extraction still controls the exposure - so we measure it, we do not eyeball it. Condition, capture and face velocities, transport velocity and static pressure are checked against the design intent under HSG258, and the result is written up and labelled on the plant.

We test to the HSE's guidance, HSG258, and the job ends in a report and a label on the plant: what was measured, what passed, what needs putting right, and the date the next test falls due.

  • The system examined end to end - hood to discharge
  • Capture and face velocities measured at source
  • Transport velocity and static pressure recorded
  • A report, a verdict and a label with the next-due date

Examine, measure, report, label

1

Inspect

We examine the condition of the hoods, ducting, filter and fan and how each is meant to control its process.

2

Test

We measure capture and face velocities, transport velocity and static pressure at every key point.

3

Assess

The readings are judged against the design benchmark under HSG258, with a clear pass or fail on control.

4

Certify

The plant is labelled and you get the report and next-due date for your COSHH records.

Frequently asked questions

How often does LEV need testing?

At least every 14 months for most systems, sooner for higher-risk work such as heavy welding. We match the interval to the process and label the next-due date on the plant.

What does the test measure?

The condition of hoods, ducts, filters and fan, and measured capture, face, transport and static-pressure readings - all weighed against how the LEV should perform to control the exposure.

What if a point fails?

We set out what failed and why, usually a single reading, so it can be corrected, then re-test to confirm control before certifying.

Do you cover the Broughton and Hawarden Airport units?

Yes - the aerospace, engineering and vehicle units across the area, and the wider North Wales.

Do you only test welding extraction?

No - weld fume, machining and coolant mist, grinding and composite dust, paint spray, fume cupboards and salon and dental extraction all fall under the same duty.

LEV testing in Hawarden

In and around Hawarden

The Broughton and Hawarden Airport units carry the area's aerospace, welding, machining and vehicle trades, the fume, mist and dust drawn off wherever it is raised. We test to HSG258 so those lines can prove their extraction holds what their people would otherwise breathe.

20+ years of experience

We have carried out LEV thorough examination and testing to HSG258 since 2001, across North Wales and the UK. From a machine shop to a joinery, a spray booth or a lab fume cupboard, the job ends the same way: measured readings, a clear verdict, and a label whose next-due date you can rely on.

Book your Hawarden LEV thorough examination

Tell us what you run and we will examine, measure, report and label it to HSG258 - across North Wales.