LEV Testing · Kenilworth
The Common Lane units and technology firms around Kenilworth machine, weld, solder and finish, raising fume, mist and dust the law says must be controlled. We examine and test local exhaust ventilation to HSG258 and certify it.
Kenilworth sits in Warwickshire's technology corridor near the university science parks, and its working side is the precision-engineering, electronics and light-manufacturing units of Common Lane and the estates around the town. Their machining and welding bays, soldering stations and finishing lines all raise something their local exhaust ventilation has to capture at source.
LEV is tested hard by precision and technology work and quietly loses its edge - filters load, ducts fur, a fan tires - until a hood stops holding the exposure. We carry out thorough examination and testing to HSG258 across Kenilworth: measured capture and face velocities at the working points, a judgement against how the system was meant to perform, and a label carrying a next-due date you can trust.
CNC and manual machining raises oil mist and metal dust at the enclosure and bench that has to be captured at source.
Flour, powders and steam need capture at the mixing and process points, from bakeries to production kitchens.
Saws, sanders and routers throw fine wood dust that has to be drawn off at the tool and the bench.
Weld fume and grinding dust need capture at the arm and booth, wherever steel is fabricated.
Bodyshop spray booths and prep bays carry paint mist and solvent vapour that the extraction has to hold and clear.
Fume cupboards, safety cabinets and dental and salon extraction all count as LEV and all fall due on the same clock.
Real jobs, described by sector and area - never by a client's name.
In a Common Lane precision unit, the coolant-mist extraction over the machining centres needed its thorough examination. We measured capture at the enclosures and the transport velocity, found the pull down on one line, set the fix, and re-tested before certifying.
A Kenilworth electronics cell needed its solder-fume extraction testing. We measured capture at each tip, checked the airflow, and labelled the system with the readings and next-due date.
Condition of hoods, ducting, filters and fan - the damage, blockage and wear that quietly drops performance.
Measured capture and face velocities at the working points, plus transport velocity and static pressure through the system.
The readings assessed against how the LEV should perform to actually control the exposure - not just whether the fan turns.
Where the process warrants it, sampling to confirm the control is keeping the substance out of the breathing zone.
A thorough examination and test under COSHH is a real assessment, not a rubber stamp. It is a structured examination of the system's condition, measurement of its actual performance, and an assessment of those readings against how the system should perform to control the exposure. It follows the HSE's guidance, HSG258, and ends in a report and a label.
We test to the HSE's guidance, HSG258, and the job ends in a report and a label on the plant: what was measured, what passed, what needs putting right, and the date the next test falls due.
We examine the hoods, ducting, filter and fan and identify how each is meant to control its process.
We record capture and face velocities, transport velocity and static pressure at every key point.
The readings are assessed against the design intent under HSG258, with a clear verdict on control.
The plant is labelled with the result and next-due date, and you get the report for the COSHH file.
At least every 14 months for most systems, sooner for higher-risk work such as heavy welding. We match the interval to the process and label the next-due date on the plant.
The condition of hoods, ducts, filters and fan, and measured capture, face, transport and static-pressure readings - all weighed against how the LEV should perform to control the exposure.
We set out what failed and why, usually a single reading, so it can be corrected, then re-test to confirm control before certifying.
Yes - the precision, electronics and finishing units across Kenilworth, and the wider Warwickshire.
No - machining mist, solder and weld fume, metal and wood dust, fume cupboards and salon and dental extraction all fall under the same duty.

The Common Lane units carry Kenilworth's machining, welding and soldering trades, the fume, mist and dust of precision work drawn off wherever it is raised. We test to HSG258 so those benches can prove their extraction holds what their people would otherwise breathe.
We have carried out LEV thorough examination and testing to HSG258 since 2001, across Warwickshire and the UK. From a machine shop to a joinery, a spray booth or a lab fume cupboard, the job ends the same way: measured readings, a clear verdict, and a label whose next-due date you can rely on.
Tell us what you run and we will examine, measure, report and label it to HSG258 - across Warwickshire.