Phoenix Cleaning Company Call 07961 915018
LEV Testing in Richmond

LEV Testing · Richmond

LEV testing in Richmond.

From the cabinetmaking and French-polishing shops to the engineering and finishing units, Richmond workplaces raise fume, mist and dust that the law says must be controlled - and the control proven by a thorough examination and test.

HSG258 examinationMeasured airflow readingsReport & labelFully insured

Where fume and dust control sits in Richmond

Richmond keeps a fine cabinetmaking trade, and a workshop among the estates machines hardwood and French-polishes the finished piece in shellac and spirit. Where a workshop machines hardwood and applies shellac in spirit the dust and vapour are real - hardwood dust is a known carcinogen off the saws and sanders, and the French polish gives off a spirit vapour at the bench - and the estate's engineering and finishing units add weld fume, oil mist and grinding dust, all things a worker should not breathe.

Local exhaust ventilation is what captures it at source, and the law does not take the control on trust. Under COSHH the wood-dust extraction, the polishing-bench capture and the engineering extraction have to be thoroughly examined and tested at least every 14 months, measured against how they are used, not just switched on and assumed to work.

The Richmond workplaces that need an LEV test

01

Precision engineering

CNC and manual machining raises oil mist and metal dust at the enclosure and bench that has to be captured at source.

02

Food and drink production

Flour, powders and steam need capture at the mixing and process points, from bakeries to production kitchens.

03

Woodworking and joinery

Saws, sanders and routers throw fine wood dust that has to be drawn off at the tool and the bench.

04

Welding and fabrication

Weld fume and grinding dust need capture at the arm and booth, wherever steel is fabricated.

05

Vehicle body and paint

Bodyshop spray booths and prep bays carry paint mist and solvent vapour that the extraction has to hold and clear.

06

Laboratory and clinical

Fume cupboards, safety cabinets and dental and salon extraction all count as LEV and all fall due on the same clock.

What we have tested around Richmond

Real jobs, described by sector and area - never by a client's name.

Cabinetmaking workshop · Richmond area

A hardwood-dust and shellac-vapour test

At a cabinetmaking workshop on the Gallowfields estate near Richmond, machining hardwood and French-polishing in spirit, the wood-dust extraction and the polishing-bench capture had lost draw and hardwood dust and shellac vapour were reaching the operators. We measured capture at the saws and sanders and the polishing bench, checked the ducting and the filters, and found a fan below duty dragging the run. We set out the remedial action, and re-tested to confirm the control before certifying.

Engineering unit · Richmond area

A weld-fume and mist extraction test

At an engineering unit on the Gallowfields estate near Richmond, the weld-fume arms and mist extraction over the machining had lost capture and the shop was hazing by mid-shift. We measured capture and face velocities at each point, checked the ducting and the filters, and reported what needed putting right so it held its spec on a re-test.

What a thorough examination and test measures in Richmond

01

Visual and structural

Condition of hoods, ducting, filters and fan - the damage, blockage and wear that quietly drops performance.

02

Quantitative performance

Measured capture and face velocities at the working points, plus transport velocity and static pressure through the system.

03

Benchmark to design

The readings assessed against how the LEV should perform to actually control the exposure - not just whether the fan turns.

04

Air sampling, where needed

Where the process warrants it, sampling to confirm the control is keeping the substance out of the breathing zone.

LEV extraction arm and capture hood tested in Richmond

Fourteen months, and whose name is on it

A thorough examination and test under COSHH is a real assessment, not a rubber stamp. It is a structured examination of the system's condition, measurement of its actual performance, and an assessment of those readings against how the system should perform to control the exposure. It follows the HSE's guidance, HSG258, and ends in a report and a label.

We test to the HSE's guidance, HSG258, and the job ends in a report and a label on the plant: what was measured, what passed, what needs putting right, and the date the next test falls due.

  • Visual and structural examination of hoods, ducting, filter and fan
  • Measured airflow, capture and face velocities at the working points
  • Static pressure and duct transport velocity readings recorded
  • Report against the benchmark, with a label and the next-due date

Examine, measure, report, label

1

Inspect

We examine the hoods, ducting, filter and fan and identify how each is meant to control its process.

2

Take readings

We record capture and face velocities, transport velocity and static pressure at every key point.

3

Judge

The readings are assessed against the design intent under HSG258, with a clear verdict on control.

4

Label up

The plant is labelled with the result and next-due date, and you get the report for the COSHH file.

Frequently asked questions

How often does LEV have to be tested?

At least every 14 months under COSHH Regulation 9 - and sooner for certain higher-risk processes. We set the right interval for what you run and put the next-due date on the label and the report.

What do we get at the end?

A thorough-examination-and-test report against HSG258, a pass/fail on each point with any remedials listed, and a dated label on the plant showing when the next test falls due.

What if a point fails?

We set out exactly what failed and why - often a single reading such as static pressure or capture velocity - so it can be put right, and we re-test to confirm the control before certifying.

Do you cover the the Gallowfields industrial estate and the wider town?

Yes - the the Gallowfields industrial estate and the town's units, and across Richmond and the wider North Yorkshire.

Do you only test engineering extraction?

No - any LEV: welding fume arms, wood and grain dust systems, spray booths, mist extraction, fume cupboards, and dental and salon extraction all fall under the same duty and the same clock.

LEV testing in Richmond

In and around Richmond

Richmond keeps a cabinetmaking trade and a run of engineering units on the Gallowfields estate, machining hardwood, French-polishing, welding and machining - raising hardwood dust, shellac vapour, weld fume and oil mist. Every one carries a duty to control what its work throws off - and to prove it with a measured test.

20+ years of experience

We have carried out LEV thorough examination and testing to HSG258 since 2001, across North Yorkshire and the UK. From a machine shop to a joinery, a spray booth or a lab fume cupboard, the job ends the same way: measured readings, a clear verdict, and a label whose next-due date you can rely on.

Book your Richmond LEV thorough examination

Tell us what you run and we will examine, measure, report and label it to HSG258 - across North Yorkshire.