Home / LEV Testing / Guide
LEV testing - plastics processing
Melting and moulding plastic is not a clean process. As the polymer is heated and processed, it gives off fume and volatile organic compounds - styrene, formaldehyde and others depending on the plastic - that are a real health hazard to the people working nearby. Extraction at source controls it, and like any LEV, that extraction needs testing to prove it works. Here is why.
The short answer
Processing plastic - injection moulding, extrusion and similar - heats the polymer, and hot plastic releases fume and volatile organic compounds (VOCs) into the air. The specific substances depend on the plastic: styrene from ABS and polystyrene, formaldehyde from POM, and a range of others, many of them a respiratory and health hazard, with some raising longer-term concerns on prolonged exposure. Because these are hazardous substances, they fall under COSHH, which requires exposure to be controlled - and the standard control is local exhaust ventilation (LEV): a hood capturing the fume at the machine, ducting carrying it away, and a fan and filter. Like any LEV controlling a COSHH hazard, plastics fume extraction has to be tested - a thorough examination and test, normally at least every 14 months - to confirm it is actually capturing the fume and protecting the workers. Testing is what proves the extraction works, rather than merely being present.
Hot plastic gives off fume
When plastic is processed - heated to melt it and formed into shape, as in injection moulding or extrusion - the heat drives off fume and volatile organic compounds from the polymer. This is inherent to the process: heating plastic to working temperature releases some of the compounds within it, and the hotter the process runs, the more is released, with overheating making it markedly worse. The result is airborne fume and VOCs around the machine, which the operators and others nearby can breathe. So plastics processing, for all that it may look clean, generates a hazardous emission that has to be controlled - the fume is a genuine occupational health matter, not just an odour.
The specific substances depend on the plastic being processed. Styrene comes off ABS and polystyrene - it is behind the sweet chemical smell often noticed around these plastics, and is a recognised health hazard. Formaldehyde can be released from POM (acetal). Other plastics release other VOCs, with more than fifty different compounds identifiable across the range of plastics. Many of these are respiratory irritants and health hazards, causing short-term effects like headaches, eye and throat irritation, and raising longer-term health concerns on prolonged exposure. So the fume from plastics processing is a real and varied hazard, and which substances are present depends on what is being moulded - which is part of why the extraction controlling it needs to be assessed and tested for the actual process.
It falls under COSHH
Because the fume and VOCs from plastics processing are hazardous to health, they fall under the Control of Substances Hazardous to Health Regulations - COSHH - which govern hazardous substances at work. COSHH requires an employer to assess the risk from the hazardous substance and to control exposure to it, preventing it where reasonably practicable and adequately controlling it where not. So a business processing plastic has a duty to control its workers' exposure to the fume, not simply to accept it as part of the job. The fume being a byproduct of the process does not exempt it - it is a hazardous substance the business is exposing people to, and COSHH applies.
Controlling the exposure, under COSHH, means engineering control at source wherever reasonably practicable - capturing the fume where it is generated before it spreads into the workroom air. General ventilation of the workshop is not adequate control for a hazardous fume, because it lets the fume disperse into the air people breathe before diluting it; the recognised control is to capture the fume at source with local exhaust ventilation. So COSHH effectively points plastics processors toward LEV as the control for the fume - extraction that catches the fume at the machine. And COSHH does not stop at requiring the control to exist: it requires the control to be effective and maintained, which is where testing comes in. The duty is to control the exposure, and LEV is how, but only if the LEV actually works.
LEV captures the fume at source
The local exhaust ventilation that controls plastics fume works on the same principle as any LEV: capture the contaminant at source and carry it away. In practice this means a hood or capture point positioned at the machine, close to where the fume is released - at the injection moulding nozzle area, the die, or wherever the hot plastic gives off fume - drawing the fume in before it escapes into the workroom. Ducting carries the captured fume away, and a fan provides the airflow, with filtration or treatment as needed before the air is discharged. The aim is that the fume is caught where it is made and removed, so it does not reach the operators' breathing zone.
For this to control the exposure, the LEV has to be designed and set up for the actual process - positioned to capture the fume where it is released, with enough airflow to draw it in against the way the fume rises and drifts. The capture velocity at the source has to be adequate to catch the fume, the hood placed where the fume actually comes off, and the whole system sized to convey the fume away. A poorly positioned or under-powered hood will let fume escape past it into the workroom, failing to control the exposure despite being present. So the effectiveness of plastics fume LEV depends on it being properly matched to the process - which is exactly the kind of thing that has to be checked, not assumed. Extraction that looks like it should work is not the same as extraction proven to capture the fume.
Why it has to be tested
Under COSHH, LEV controlling a hazardous substance must be maintained in effective working order and, for most LEV, given a thorough examination and test at suitable intervals - normally at least every 14 months. This applies to plastics fume extraction as to any other LEV: it is not enough to have the extraction; it has to be tested to prove it is actually capturing the fume and controlling the exposure. The test measures the system's performance - the capture at the hoods, the airflow, the transport in the ducts - and checks it against what is needed to control the fume, confirming the LEV is doing its job or identifying where it is falling short.
This testing matters because an LEV system's performance can degrade over time without being obvious - a fan wearing, a duct partly blocked, a filter loading, a hood moved or damaged - so extraction that once controlled the fume may quietly stop doing so. Testing catches this, verifying that the system still captures the fume adequately, so the workers are genuinely protected rather than assumed to be. And it provides the evidence that the employer is meeting the COSHH duty to control exposure and maintain the control. So plastics and injection moulding fume extraction needs LEV testing for the same reasons any LEV does: to prove the control works, to catch degradation before it leaves people exposed, and to evidence compliance. The fume is a real hazard, the LEV is the control, and the test is what confirms the control is real.
The takeaway
Processing plastic releases fume and VOCs - styrene from ABS and polystyrene, formaldehyde from POM, and many others depending on the plastic - that are a real health hazard to the people working nearby, worse the hotter the process runs. Because these are hazardous substances, they fall under COSHH, which requires the exposure to be controlled, and the recognised control is local exhaust ventilation: a hood capturing the fume at the machine, ducting carrying it away, a fan and filter. General ventilation of the workshop is not adequate for a hazardous fume - it has to be captured at source.
And like any LEV controlling a COSHH hazard, plastics fume extraction has to be tested - a thorough examination and test, normally at least every 14 months - to prove it is actually capturing the fume and protecting the workers. Testing matters because a system's performance can degrade unnoticed, so extraction that once worked may quietly stop controlling the fume; the test catches that and evidences compliance. So plastics and injection moulding fume extraction needs LEV testing for the same reasons any LEV does: the fume is a real hazard, the LEV is the control, and the test is what confirms the control is real, not just present.
Questions
Fume and volatile organic compounds released as the polymer is heated - the specific substances depending on the plastic. Styrene comes off ABS and polystyrene, formaldehyde from POM, and a range of others across different plastics. Many are respiratory irritants and health hazards, causing short-term effects like headaches and eye and throat irritation, with longer-term concerns on prolonged exposure.
Because the fume and VOCs are substances hazardous to health, and COSHH governs hazardous substances at work. It requires the employer to assess the risk and control exposure - preventing it where reasonably practicable and adequately controlling it where not. The fume being a byproduct of the process does not exempt it: it is a hazardous substance people are being exposed to, so COSHH applies.
Because general ventilation lets the fume disperse into the air people breathe before diluting it, which is not adequate control for a hazardous fume. COSHH points to engineering control at source - capturing the fume where it is generated, before it spreads. Local exhaust ventilation does that: a hood at the machine catches the fume, ducting carries it away, and a fan and filter complete the system.
Yes. Under COSHH, LEV controlling a hazardous substance must be maintained in effective working order and given a thorough examination and test at suitable intervals - normally at least every 14 months. Plastics fume extraction is no exception: it has to be tested to prove it is actually capturing the fume and controlling the exposure, not merely present.
Because an LEV system's performance can degrade over time without being obvious - a fan wearing, a duct partly blocked, a filter loading, a hood moved or damaged - so extraction that once controlled the fume may quietly stop. Testing catches this by measuring the actual capture and airflow, verifying the workers are genuinely protected rather than assumed to be.
The system's performance against what is needed to control the fume - the capture at the hoods, the airflow, the transport velocity in the ducts, and static pressures - confirming the LEV is capturing the fume adequately or identifying where it falls short. It also provides the evidence that the employer is meeting the COSHH duty to control exposure and maintain the control.
Plastics processing fume is a COSHH hazard controlled by LEV - our thorough examination and test proves the extraction is capturing the fume at source and protecting your operators, not just present.