LEV testing - performance
The dangerous LEV system is not the one that has obviously failed - that gets fixed. It is the one that still hums, still pulls a bit of air, and quietly stops protecting anyone. Here is what that costs while nobody notices.
The short answer
An LEV system that sort of works - running, moving some air, but no longer capturing the contaminant at source - is the most expensive state a system can be in. It costs you in exposure that harms people without warning, in energy wasted running plant that is not doing its job, and in false compliance, because it looks fine and gives everyone confidence it does not deserve. A proper test is what exposes it.
Cost one
The whole point of LEV is to capture fume, dust, mist or vapour at source before anyone breathes it. A system that under-performs - a hood pulling below its design velocity, a blocked filter, a fan losing power - can still look and sound like it is working while letting contaminant escape into the air people breathe. Nobody sees it, because the system appears to be on.
That is the real danger. Overexposure to these substances causes occupational illness - asthma, lung disease, long-latency conditions - that develops quietly over time. A system that sort of works exposes people day after day without any obvious sign, which is exactly why measured testing, not a glance, is the only way to know it is doing its job.
Cost two
An underperforming LEV system still draws power. Fans run, ducting carries air, and the electricity bill arrives whether or not the system is actually controlling exposure. When a system is degraded - clogged filters, leaking ductwork, a tired fan - it can work harder and cost more while delivering less, which is the worst of both worlds.
Keeping a system properly maintained and tested is therefore an efficiency measure as well as a safety one. A system that is running is not free; a system that is running without protecting anyone is pure cost.
Cost three
A system that appears to work breeds confidence it has not earned. Managers assume people are protected, workers assume the extraction is doing its job, and the duty feels met - so nobody investigates. That false confidence is more dangerous than an obviously broken system, because a broken one gets reported and fixed, while a sort-of-working one is left exactly because it looks fine.
It also creates a paper risk. If exposure is later found to have harmed someone, an assumption that the system was working - with no measured evidence it actually was - is a weak position in front of an inspector or a claim. Confidence without measurement is not compliance; it just feels like it.
Why it happens
LEV does not usually fail all at once. It drifts - filters gradually load, ductwork slowly leaks or partially blocks, a fan loses efficiency, a hood gets moved slightly or a workstation is added that robs airflow from the others. Each change is small and invisible, and none of them stops the system running. The cumulative effect is a system that is well below its design performance while looking unchanged.
This is precisely why the law requires a thorough examination and test on a cycle rather than trusting appearances. Measurement catches the drift that the eye and ear cannot, before sort of working becomes not working at all.
The fix
The only reliable way to know an LEV system is actually protecting people is to measure it - a thorough examination and test that takes real readings at each capture point and judges them against what the system should achieve. That is what turns sort of works into a definite answer, and it is what surfaces the quiet degradation before it does harm.
Then the duty is to act on the result: fix the under-performing hood, change the loaded filter, repair the leaking run. A system that is measured and maintained on a cycle stays in the state you assume it is in - genuinely protecting the people who rely on it, rather than merely appearing to.
The missing baseline
Part of why under-performance goes unnoticed is that many systems have no baseline to compare against. When an LEV system is installed or altered, its performance should be established by commissioning, and that benchmark is what every later test measures against. Without it, there is no way to say whether a reading is healthy or already degraded - the system has no known good state to have drifted from.
This is why a first test on an older, never-commissioned system is so valuable, and sometimes sobering: it establishes for the first time whether the system is actually controlling exposure, rather than assuming it has been all along. Setting and keeping that benchmark turns future tests from a guess into a genuine measure of change.
Questions
Because the cost is invisible. It exposes people to contaminant without any obvious sign, wastes energy running plant that is not controlling exposure, and creates false confidence that the duty is met - all while the system looks fine.
LEV degrades quietly - filters load, ductwork leaks or blocks, fans lose power, hoods get moved or airflow is robbed by an added workstation. The system still runs and moves some air while capturing far less than it should.
A broken system gets reported and fixed; a sort-of-working one is left because it looks fine. That false confidence means exposure continues, and an assumption of protection with no measured evidence is a weak position if harm is later found.
Only by measuring it - a thorough examination and test that takes readings at each capture point and judges them against what the system should achieve. Appearances cannot tell you.
It can. Fans and plant still draw power, and a clogged or leaking system may work harder while delivering less protection - cost without benefit.
Act on it: fix the under-performing hood, change the loaded filter, repair the leaking run. Measuring and maintaining on a cycle keeps the system genuinely protecting people.
We measure each capture point against its design performance, so a system that only looks like it works is caught before it costs you.