Duct cleaning - ventilation
When extraction feels weak, the instinct is to fit a bigger fan. But an oversized fan is not free performance - it quietly costs you in energy, comfort and balance, and often does not fix the real problem.
The short answer
An oversized extraction fan seems like useful headroom but carries hidden costs. It draws more power than the system needs, pulls out heated or cooled air you have paid to condition, and can overwhelm the make-up air supply so the building goes into negative pressure. It often runs noisier too. And if the real problem was a dirty or poorly designed system, a bigger fan masks it rather than fixing it.
The instinct
When a kitchen is smoky or a workspace stuffy, the obvious diagnosis is not enough extraction, and the obvious fix is a bigger fan. It feels like buying headroom - more power, more margin, problem solved. Sometimes the system genuinely is undersized and more capacity is right. Often, though, the instinct leads to an oversized fan that creates a new set of problems while masking the old one.
The trouble is that extraction is a balanced system, not a single dial you turn up. A fan far larger than the ductwork and make-up air were designed for does not simply give more of a good thing - it pushes the whole system out of the balance it needs to work well, and the costs of that show up quietly rather than obviously.
Cost one
An oversized fan costs more to run, straightforwardly - a larger motor moving more air draws more power, often for capacity that is never actually needed. But the bigger, hidden energy cost is what it extracts. Every cubic metre of air pulled out of a building is a cubic metre that has to be replaced, and in a heated or cooled space that replacement air has to be conditioned all over again.
So an oversized extract fan does not just waste electricity on itself - it throws away the heating or cooling you have already paid for, and makes the heating and cooling systems work harder to replace it. Over-extraction is one of the quietest and steadiest energy drains a building can have, and a fan bigger than the system needs is a common cause of it.
Cost two
Extraction only works if the air removed is replaced by make-up air, and the make-up air supply is sized for the extraction the system was designed for. Fit a fan that pulls far more than that, and the building cannot supply enough replacement air - so it goes into negative pressure. Doors become hard to open, draughts are pulled in through every gap, and the extraction itself cannot reach its intended flow because it is starved of air to move.
In a gas kitchen this is more than an inconvenience: adequate make-up air is a safety requirement tied to the gas interlock, and an extraction system pulling harder than the make-up air allows can undermine that balance. An oversized fan can therefore create a ventilation and safety problem in the course of trying to solve a capacity one.
Cost three
Oversized fans tend to be noisier - more air moved at higher velocity means more noise through the ductwork and at the discharge, which can be a nuisance to staff, neighbours and customers. Running a system harder than it was designed for can also accelerate wear on the fan and stress the ductwork.
The subtler cost is what a bigger fan hides. If extraction felt weak because the ductwork was greasy and choked, or because the system was poorly designed or balanced, a larger fan can brute-force enough airflow to mask the symptom without touching the cause. The underlying problem - the dirty duct, the design flaw - remains, now behind a fan that is more expensive to run and papering over it.
The better approach
The sensible response to weak extraction is to find out why before reaching for a bigger fan. Very often the cause is a system that is dirty rather than undersized - grease-choked ductwork and a fouled fan cutting the airflow the existing system should deliver. Cleaning restores that airflow at a fraction of the cost of a new fan, and without any of the energy, balance and noise penalties.
Where the system genuinely is undersized, the fix is to size the fan to the ductwork and make-up air as a balanced whole, not simply to fit the biggest one available. Bigger is not better; matched is better. Diagnosing the real cause - very often cleaning - usually solves the problem more cheaply and completely than upsizing ever would.
Questions
No. An oversized fan wastes energy, over-extracts heated or cooled air, can overwhelm the make-up air supply and push a building into negative pressure, and often runs noisier - while frequently masking the real problem rather than fixing it.
It draws more power for capacity that is not needed, and it extracts more conditioned air - heating or cooling you have already paid for - which then has to be replaced and reconditioned. Over-extraction is a steady, hidden drain.
When a fan extracts more air than the make-up supply can replace, the building drops below outside pressure. Doors become hard to open, draughts are pulled in, and the extraction is starved - and in gas kitchens it can undermine the make-up air and interlock balance.
Yes. If extraction felt weak because the ductwork was greasy and choked or the system was poorly designed, a larger fan can force enough airflow to mask the symptom while leaving the cause - the dirty duct or design flaw - in place.
Diagnose the cause first. Very often it is a dirty system rather than an undersized one - cleaning the choked ductwork and fouled fan restores the airflow the existing system should deliver, far cheaper than a new fan.
Then size the fan to the ductwork and make-up air as a balanced whole, rather than fitting the biggest available. Matched is better than bigger - a balanced system performs without the energy, noise and pressure penalties.
We clean the ductwork and fan to restore the airflow you already have - before anyone fits a bigger fan you may not need.