Phoenix Cleaning Company

Home / LEV Testing / Guide

LEV testing - welding fume enforcement

The HSE welding fume enforcement crackdown, explained

In 2019, the HSE changed its position on welding fume in a way that took many workshops by surprise: it reclassified all welding fume, mild steel included, as a carcinogen, and made clear that general workshop ventilation is no longer enough - indoor welding needs engineering control. It is why so many welding operations now need proper fume extraction. Here is what changed, and what it means.

2019
The change
All welding fume
A carcinogen
General vent
No longer enough
Established 2001UK-wideFully insuredCertificated and photographed

The short answer

In 2019 the HSE reclassified all welding fume as carcinogenic and strengthened its expectation that indoor welding be controlled with engineering measures like LEV

In February 2019, following evidence from the International Agency for Research on Cancer that welding fume causes cancer, the HSE issued a safety alert reclassifying all welding fume - including mild steel welding fume, previously thought less harmful - as a carcinogen. With that, it strengthened its enforcement expectation: because general ventilation does not adequately control a carcinogenic fume, all indoor welding now needs suitable engineering controls, principally local exhaust ventilation (LEV), to control the fume at source. This was a significant change because, before it, mild steel welding fume was often controlled with just general ventilation, which is no longer accepted. So the change means that welding operations that got by on general ventilation now need proper fume extraction, and that HSE inspectors expect to see engineering control of welding fume wherever welding is done indoors. For a welding business, it means treating welding fume as the carcinogen it now is - controlling it at source with LEV, and maintaining and testing that LEV, as with any control of a carcinogenic substance.

What changed in 2019

Fume reclassified as carcinogenic

The change came in February 2019, when the HSE issued a safety alert changing its position on welding fume. It followed new scientific evidence - from the International Agency for Research on Cancer - that exposure to welding fume can cause cancer in humans, specifically lung cancer, with possible links to kidney cancer too. On the strength of this, the HSE reclassified all welding fume as a carcinogen. Crucially, this included mild steel welding fume: previously, mild steel welding fume had been regarded as less harmful than fume from stainless steel or other materials, and was often treated more leniently - but the new evidence and reclassification applied to all welding fume, mild steel included. So the change swept up the most common kind of welding, which many workshops did every day.

This reclassification was the heart of the change: welding fume went from being treated as a general respiratory hazard, with mild steel fume seen as relatively low-risk, to being treated as a carcinogen across the board. That shift in classification is what drove everything else, because a carcinogen has to be controlled far more stringently than a general nuisance dust or fume - the duty for a carcinogen is to reduce exposure as low as reasonably practicable, not merely to a general limit. So by reclassifying welding fume as carcinogenic, the HSE effectively raised the bar for how welding fume must be controlled, for all welding, including the mild steel welding that is so common. Understanding this reclassification is the key to understanding the enforcement change that followed: it is because the fume is now a carcinogen that the control expectations became stricter.

General ventilation is no longer enough

The control expectation rose

The practical consequence of the reclassification was a strengthened enforcement expectation about how welding fume must be controlled - and specifically, that general ventilation is no longer enough. Before the change, mild steel welding fume was often controlled simply by general ventilation of the workshop - opening doors, extractor fans in the roof, general air movement to dilute the fume. With welding fume now a carcinogen, the HSE made clear that general ventilation does not achieve the necessary control: diluting a carcinogenic fume into the workshop air, where people still breathe it, is not adequate control of a cancer-causing substance. So the expectation rose from general ventilation to engineering control at source.

Engineering control at source means capturing the fume where it is generated, at the arc, before it disperses - which in practice means local exhaust ventilation (LEV): fume extraction positioned to catch the fume at the welding point. This is the control the HSE now expects for indoor welding, and it applies with immediate effect to all welding indoors, mild steel included. So the change is not just a reclassification on paper but a concrete shift in what workshops must do: from relying on general ventilation to installing and using proper fume extraction that captures at source. This is why so many welding operations have had to fit LEV since 2019 - the general ventilation that was accepted before is no longer sufficient for a fume now classed as carcinogenic. The bar for controlling welding fume rose, and engineering control at source is what now meets it.

Before
General vent often used
Now
Engineering control expected
Means
LEV at source

What it means for a welding business

Control, maintain, test

For a welding business, the change means treating welding fume as the carcinogen it now is - which brings concrete duties. First, control the fume at source with engineering control, principally LEV, wherever welding is done indoors, including mild steel welding. Relying on general ventilation is no longer acceptable, so a business that welded indoors under general ventilation needs to provide proper fume extraction. LEV and respiratory protective equipment are complementary - LEV controlling the fume at source for everyone, RPE protecting the individual welder - and for a carcinogenic fume, controlling exposure as low as reasonably practicable is the aim, which points to LEV as the primary control.

Second, because the LEV controls a carcinogenic substance, it falls under the same duties as any LEV controlling a hazardous substance: it must be maintained in effective working order and given a thorough examination and test at suitable intervals, normally at least every 14 months, to prove it keeps capturing the fume. So it is not enough to fit fume extraction - it has to be kept working and tested. HSE inspectors, since the change, expect to see engineering control of welding fume in place and working wherever welding is done indoors, so a business needs both the LEV and the evidence it is maintained and effective. So the enforcement change means, for a welding business: control the fume at source with LEV, use RPE alongside, and maintain and test the LEV to prove it works. This is the standard now expected, driven by the reclassification of welding fume as a carcinogen - and it applies to the everyday mild steel welding that was previously treated more leniently.

Why it matters

A real hazard, taken seriously

Behind the regulatory change is a real health reason: welding fume genuinely causes cancer, and welders are exposed to it every day. The reclassification and enforcement change were not bureaucratic tightening for its own sake but a response to evidence that welders were being exposed to a carcinogen, often without adequate control - particularly in mild steel welding, where the fume had been underestimated. So the change matters because it addresses a real risk to welders' health: controlling the fume at source protects them from breathing a cancer-causing substance day in, day out, which the previous reliance on general ventilation did not adequately do.

For a welding business, this gives the change its weight: it is not just about satisfying an inspector but about protecting the welders from a serious, lasting harm. Meeting the expectation - proper fume extraction, maintained and tested - is how a business both complies with the strengthened enforcement and genuinely protects its people from welding fume's cancer risk. So the sensible response is to take the change seriously as what it is: recognition that welding fume is a carcinogen requiring proper control, and a requirement to provide that control. A business that fits LEV, uses RPE, and maintains and tests the LEV is meeting the new standard and protecting its welders - dealing with a real hazard properly. The enforcement crackdown, understood this way, is the health protection of welders catching up with the evidence, and the response to it is to control the fume properly, at source, and keep proving that control works.

The takeaway

Control welding fume at source now

In February 2019, the HSE reclassified all welding fume - mild steel included - as a carcinogen, following evidence that it causes cancer, and strengthened its enforcement expectation: because general ventilation does not adequately control a carcinogenic fume, all indoor welding now needs engineering control at source, principally local exhaust ventilation. This was a significant change because mild steel welding fume, the most common kind, had been treated relatively leniently and often controlled with just general ventilation - which is no longer accepted. So welding operations that got by on general ventilation now need proper fume extraction, and HSE inspectors expect to see engineering control of welding fume wherever welding is done indoors.

For a welding business, it means treating welding fume as the carcinogen it now is: controlling it at source with LEV, using RPE alongside to protect the individual welder, and maintaining and testing the LEV - normally at least every 14 months - to prove it keeps capturing, as with any control of a carcinogenic substance. Behind the change is a real health reason: welding fume genuinely causes cancer, and welders are exposed daily, so proper control protects them from a serious, lasting harm the previous reliance on general ventilation did not. So the response to the enforcement change is straightforward: control welding fume at source now, with maintained and tested LEV - meeting the standard now expected, and genuinely protecting the welders it exists to protect.

More guides

Read next

Questions

Frequently asked questions

What changed with welding fume in 2019?

In February 2019, following evidence from the International Agency for Research on Cancer that welding fume causes cancer, the HSE reclassified all welding fume - including mild steel welding fume, previously thought less harmful - as a carcinogen, and strengthened its enforcement expectation that indoor welding be controlled with engineering measures like LEV, not just general ventilation.

Why did mild steel welding fume matter in the change?

Because mild steel welding fume had previously been regarded as less harmful than fume from stainless steel or other materials, and was often treated more leniently - but the new evidence and reclassification applied to all welding fume, mild steel included. So the change swept up the most common kind of welding, which many workshops did every day, raising how it must be controlled.

Why is general ventilation no longer enough?

Because general ventilation dilutes the fume into the workshop air, where people still breathe it, which is not adequate control for a carcinogenic substance. With welding fume now classed as a carcinogen, the duty is to control exposure as low as reasonably practicable, which means capturing the fume at source with engineering control - local exhaust ventilation - not diluting it with general air movement.

What does a welding business need to do now?

Control the fume at source with LEV wherever welding is done indoors, mild steel included; use RPE alongside to protect the individual welder; and maintain and test the LEV - normally at least every 14 months - to prove it keeps capturing, since it controls a carcinogenic substance. HSE inspectors expect to see engineering control of welding fume in place and working, with evidence it is maintained and effective.

Is this just about satisfying inspectors?

No - behind it is a real health reason: welding fume genuinely causes cancer, and welders are exposed daily, often without adequate control before the change, especially in mild steel welding. So meeting the expectation - proper fume extraction, maintained and tested - is how a business both complies and genuinely protects its welders from a serious, lasting harm the previous reliance on general ventilation did not.

How does the LEV requirement connect to testing?

Because LEV controlling a carcinogenic substance falls under the duty to maintain it in effective working order and give it a thorough examination and test at suitable intervals - normally at least every 14 months. So it is not enough to fit fume extraction; it has to be kept working and tested to prove it keeps capturing the fume. The control and its testing go together.

Meet the standard now expected

Since 2019, indoor welding needs engineering control of the fume, maintained and tested - our LEV testing proves your welding fume extraction is capturing at source, meeting the standard now expected.