Home / Duct Cleaning / Guide
Duct cleaning - kitchen heat
A commercial kitchen runs hot, and when it runs too hot, operators often misread why - putting it down to the weather, turning the extract fan up and expecting more, or overlooking the make-up air that the extraction depends on. These misreadings leave the kitchen hot and the real cause unaddressed. Here is what operators commonly get wrong about kitchen heat and ventilation, and what is actually going on.
The short answer
A commercial kitchen is hot because the cooking constantly generates heat, and the ventilation's job is to remove it - so when a kitchen runs too hot, it is usually a ventilation problem. But operators commonly misread that problem in a few recurring ways, and the misreadings leave the heat unaddressed. The first mistake is blaming the weather - treating a hot kitchen as just a summer problem to endure, when the heat is generated continuously by the cooking and is a ventilation matter year-round; the weather adds to it but is rarely the whole story. The second is over-relying on the extract fan - assuming that if the kitchen is hot, turning the extraction up (or that a bigger extract fan) will fix it, when the extraction can only remove air as fast as make-up air comes in to replace it. The third, and the most commonly overlooked, is ignoring make-up air - not realising that the extraction depends on a balanced supply of replacement air, so a kitchen short of make-up air has a starved extraction that cannot clear the heat however powerful the fan. The fourth is neglecting the ductwork - not seeing that a grease-clogged extract duct quietly loses airflow over time, so the extraction weakens and the kitchen gets hotter gradually, with the cause hidden inside the duct. What ties these together is a failure to diagnose: the kitchen is hot, so the operator reaches for the obvious lever (crank the fan, blame the season) rather than working out why the ventilation is not clearing the heat. The real cause is usually in the balance and condition of the system - make-up air and clean ductwork - not in the extract fan alone or the weather. Getting the heat down means diagnosing that, rather than the common misreadings.
Key points
Mistake one
The first common mistake is to blame the weather - to treat a hot kitchen as simply a consequence of a hot day, something to endure in summer and forget in winter. It is true that hot weather makes a kitchen hotter, and that the problem is often most acute in summer. But the bulk of a commercial kitchen's heat does not come from the weather; it comes from the cooking - the ovens, ranges, fryers and grills radiating heat into the space continuously, all year round. So a kitchen that is uncomfortably hot has a heat load generated mainly inside it, which the ventilation is supposed to remove, and the weather is an addition to that load rather than its source. Treating the heat as a weather problem misplaces the cause and, worse, implies there is nothing to be done but wait for cooler days.
This matters because it leads operators to endure a hot kitchen rather than diagnose it. If the heat is just the weather, you tolerate it; if the heat is the ventilation not clearing the cooking's heat load, you can do something about it. The tell is a kitchen that is too hot even in mild weather, or that has got hotter over time regardless of the season - both point to a ventilation problem, not a weather one. So the first thing to get right is the framing: a persistently or increasingly hot kitchen is a ventilation matter, driven by the cooking's continuous heat load, not merely a seasonal discomfort. The weather adds to it, but the ventilation is what is supposed to handle the load - so if the kitchen is too hot, the question is why the ventilation is not clearing the heat, not simply how hot it is outside. Blaming the weather closes off that question; recognising the ventilation cause opens it.
Mistake two and three
The second mistake is over-relying on the extract fan - assuming that if the kitchen is hot, the answer is simply more extraction: turn the fan up, or fit a bigger one, and the heat will go. This misunderstands how extraction works, because an extract fan can only remove air as fast as replacement air comes in. If the make-up air is inadequate, the kitchen is in negative pressure, and the fan cannot achieve its rated extraction against that negative pressure however hard it is driven - so cranking it up does little, because the limiting factor is not the fan's power but the missing supply air. Operators who reach for more extraction without addressing the make-up air are pulling on a lever that is not connected to the problem, and are often puzzled when a powerful fan still leaves the kitchen hot.
This leads to the third and most commonly overlooked mistake: ignoring make-up air entirely. Make-up air is the replacement air supplied to balance the extraction, and it is half the ventilation system - the extraction cannot move air, or clear heat, without it. Yet make-up air is invisible and easy to forget: operators think about the extract canopy and fan, which they can see, and not about the supply air that feeds them, which they often cannot. So a kitchen short of make-up air - starved extraction, negative pressure, heat not cleared - is frequently misdiagnosed, with the operator blaming the extract or the weather while the real cause is the missing supply air. This is the single most common thing operators get wrong about kitchen heat: not realising that the extraction depends on make-up air, so that a heat problem is often really a make-up air problem. The fix is not a bigger extract fan but adequate, balanced make-up air to let the extraction work - which cannot be found by cranking the fan, only by looking at the whole balanced system.
Mistake four
The fourth mistake is neglecting the ductwork - not recognising that a grease-clogged extract duct quietly loses airflow over time, so the extraction weakens and the kitchen gets hotter gradually. Kitchen extract ductwork accumulates grease as it carries the greasy air from the canopy, and as the grease builds up it restricts the airflow, reducing the extraction's effective rate. This happens slowly and invisibly, inside the duct, so the kitchen gets hotter by degrees without any obvious cause - the same cooking, the same fan, but less air moving because the duct is silting up. An operator who does not connect the gradual warming to the state of the ductwork will look elsewhere for the cause, or simply accept the hotter kitchen as normal, while the real cause accumulates out of sight.
This is a mistake because it is both common and fixable: a grease-clogged duct is a frequent reason for an extraction that has weakened over time, and cleaning the ductwork restores the airflow and the extraction, bringing the heat back down. But it only gets fixed if the operator recognises the ductwork as a possible cause - which means understanding that the extraction's performance depends on the duct being clear, and that grease build-up degrades it invisibly. So the fourth thing operators get wrong is to overlook the condition of the ductwork, treating the extraction as if its performance were fixed when in fact it declines as the duct clogs. Combined with the make-up air point, this completes the picture: a kitchen's heat depends on the extraction working, and the extraction depends on both adequate make-up air (the balance) and a clean duct (the condition) - the two things operators most commonly overlook. A hot kitchen is usually a failure in one or both, not in the fan or the weather that operators tend to blame.
What to do instead
What ties all four mistakes together is a failure to diagnose - reaching for an obvious lever (crank the fan) or an easy explanation (blame the weather) rather than working out why the ventilation is not clearing the heat. The alternative is to treat a hot kitchen as a diagnostic question about the whole ventilation system: is the extraction achieving its rate, or is it starved of make-up air? Is the ductwork clear, or clogged with grease and losing airflow? Is the make-up air adequate and balanced? These are the questions that lead to the real cause, and they usually point to the balance (make-up air) or the condition (clean ductwork) rather than to the fan or the season. So the right response to a hot kitchen is to look at the system as a balanced whole, not to pull the nearest lever.
In practice this means getting the ventilation assessed properly when the kitchen runs too hot - checking the extraction's actual airflow against what it should be, the state of the ductwork, and the make-up air balance - so the real cause is found rather than guessed. Often the finding is that the make-up air is inadequate, or the ductwork is grease-clogged, or both - fixable causes that cranking the fan or blaming the weather would never have addressed. Cleaning the ductwork restores the airflow a clogged duct has lost; correcting the make-up air lets the extraction achieve its rate; and together they bring the heat down by fixing the ventilation rather than fighting the symptom. So what operators should do instead of the common misreadings is diagnose the whole system and address the real cause - which is usually the make-up air and the ductwork, the two things most commonly overlooked. Get those right, and the ventilation clears the cooking's heat as it should, and the kitchen runs as cool as it can - rather than staying hot while the operator blames the weather and turns up a starved fan.
The takeaway
A hot commercial kitchen is usually a ventilation problem - the cooking generates heat continuously and the ventilation is supposed to remove it - but operators commonly misread it. They blame the weather, when most of the heat comes from the cooking year-round; they over-rely on the extract fan, when it can only remove air as fast as make-up air comes in; they ignore make-up air, the most commonly overlooked cause, not realising the extraction depends on it; and they neglect the ductwork, not seeing that a grease-clogged duct quietly loses airflow so the kitchen gets hotter over time. Each misreading leaves the real cause unaddressed and the kitchen hot.
What ties them together is a failure to diagnose - reaching for the obvious lever or the easy explanation instead of working out why the ventilation is not clearing the heat. The real cause is usually in the balance and condition of the system: inadequate make-up air (so the extraction is starved) or a clogged extract duct (so the extraction has weakened), the two things operators most often overlook. So the answer is to diagnose the whole system - checking the extraction's airflow, the ductwork, and the make-up air balance - and fix the real cause, which usually means correcting the make-up air and cleaning the ductwork. Do that, and the ventilation clears the heat as it should; keep blaming the weather and cranking a starved fan, and the kitchen stays hot while the actual cause accumulates unaddressed.
Questions
The weather adds to it, but it is rarely the main cause. Most of a commercial kitchen's heat comes from the cooking - the ovens, ranges, fryers and grills radiating heat continuously, all year round - which the ventilation is supposed to remove. So a kitchen that is too hot has a heat load generated mainly inside it, and the weather is an addition to that load rather than its source. The tell that it is a ventilation problem, not a weather one, is a kitchen that is too hot even in mild weather, or that has got hotter over time regardless of season. Treating the heat as just the weather misplaces the cause and leaves the real, fixable ventilation problem unaddressed.
Not on its own, if the make-up air is inadequate. An extract fan can only remove air as fast as replacement air comes in, so if the kitchen is short of make-up air and in negative pressure, the fan cannot achieve its rated extraction however powerful it is - cranking it up or fitting a bigger one does little, because the limiting factor is the missing supply air, not the fan's power. This is why operators are often puzzled when a strong fan still leaves the kitchen hot: they are pulling on a lever that is not connected to the real problem. The fix is usually adequate, balanced make-up air to let the extraction work, not more extraction against a supply that cannot feed it.
Make-up air is the replacement air supplied to a kitchen to balance the air the extraction removes - and it matters because the extraction cannot clear heat without it. An extract fan can only remove air as fast as make-up air comes in; if the make-up air is inadequate, the kitchen goes into negative pressure and the extraction is starved, so it cannot clear the cooking's heat however powerful the fan. Make-up air is half the ventilation system, but it is invisible and easy to forget, so a kitchen short of it is often misdiagnosed - the operator blames the extract or the weather while the real cause is the missing supply air. It is the single most common thing operators get wrong about kitchen heat.
A kitchen extract duct accumulates grease as it carries the greasy air from the canopy, and as the grease builds up it restricts the airflow, reducing the extraction's effective rate. This happens slowly and invisibly inside the duct, so the extraction weakens over time and the kitchen gets hotter by degrees - the same cooking and the same fan, but less air moving because the duct is silting up. Because it is gradual and hidden, operators often do not connect the warming to the ductwork, and either look elsewhere or accept the hotter kitchen as normal. But it is common and fixable: cleaning the ductwork restores the airflow and the extraction, bringing the heat back down. So a duct clogged with grease is a frequent, overlooked cause of a kitchen that has got hotter.
By diagnosing the whole ventilation system rather than guessing. The questions to answer are: is the extraction achieving its designed airflow, or is it starved of make-up air? Is the ductwork clear, or clogged with grease and losing airflow? Is the make-up air adequate and balanced to the extract? Getting the ventilation assessed properly - checking the actual extraction airflow against what it should be, the state of the ductwork, and the make-up air balance - finds the real cause instead of assuming it. Often the finding is inadequate make-up air, a grease-clogged duct, or both - fixable causes that cranking the fan or blaming the weather would never have addressed. So the way to tell is to look at the balanced system as a whole.
Resist the two common reflexes - blaming the weather and cranking the fan - and instead get the ventilation looked at as a whole system. Start by considering the two most commonly overlooked causes: the make-up air (is the extraction starved of replacement air?) and the ductwork (is the extract duct clogged with grease and losing airflow?), because these are usually where the real problem lies. A cleaning contractor can inspect the ductwork and check the airflow; if the duct is grease-clogged, cleaning it often restores the extraction and improves the heat noticeably. And the make-up air should be checked alongside, because a starved extraction cannot clear heat however clean the duct. Diagnosing these beats fighting the symptom with a bigger fan.
A hot kitchen is usually a starved or clogged extraction, not the weather - we check the airflow, clean the ductwork and assess the make-up air balance to find the real cause. Ask us to look at yours.