Home / LEV Testing / Guide
LEV testing - visual inspection
It is easy to picture an LEV examination as taking measurements - airflow readings, capture velocities, numbers on a meter. But before and alongside the measurements comes a thorough visual and structural inspection of the whole system, and it is a core part of the examination in its own right. What that inspection looks at, and why it matters as much as the numbers, is worth understanding.
The short answer
A thorough examination is more than measurement - it includes a careful visual and structural inspection of the whole system. This looks at the physical condition of the hoods, ductwork, fan and filters: damage, corrosion, wear, leaks, blockages, loose or missing components, and anything that compromises the system's integrity. It matters because the physical condition determines whether the system can perform - a leaking duct, a corroded hood or a damaged fan will undermine the extraction whatever a snapshot reading says, and some problems are found by looking rather than measuring. So the visual and structural inspection works alongside the performance measurements as an equally essential part of judging whether the system is sound.
Not just readings on a meter
The mental image many people have of an LEV test is someone holding a meter to a hood and noting the airflow. That measurement is real and important, but it is only part of the examination - and taking it as the whole thing misses a great deal. A thorough examination also involves a careful visual and structural inspection of the system: a systematic look at its physical condition, from the hoods at the processes through the ductwork to the fan and the filters. This inspection is not a preliminary glance or an afterthought; it is a core element of the examination, as much a part of judging the system as the measurements are.
The reason it matters is that a system's performance depends on its physical condition, and condition is often best assessed by looking. Measurements tell you what the system is doing at the moment; the inspection tells you the state of the system that produces those numbers, and whether that state is sound or deteriorating. The two together give a fuller picture than either alone. So understanding the examination means understanding that it has this inspection dimension - a thorough, structured look at the physical system - alongside the performance measurements, each contributing something the other cannot.
What the inspection covers
The visual and structural inspection covers the whole system, part by part. At the hoods, it looks at their condition and integrity - damage, distortion, corrosion, whether they are intact and positioned as they should be. Along the ductwork, it looks for damage, corrosion, leaks at joints, dents or crushing that restrict the flow, and signs of blockage or heavy internal deposit. At the fan, it checks the physical condition - wear, damage, the state of the impeller and drive. And at the filters and air cleaner, it looks at their condition and how they are holding up. The inspection is a methodical survey of the physical integrity of every part.
It also looks at the things that hold the system together and make it work as intended: the joints and connections, the access panels, the mountings and supports, the general soundness of the installation. A system is only as good as its physical integrity - a duct that leaks, a joint that has come apart, a panel left off - so the inspection checks that the system is intact and sound as a whole, not just that its individual major components exist. This structured attention to the condition of every part is what makes it a thorough inspection rather than a casual look, and it is how physical problems that would undermine the extraction are found and recorded.
Why condition matters as much as numbers
The visual and structural inspection matters because the physical condition of the system determines whether it can perform - and some problems are found by looking, not measuring. A leaking duct loses airflow to the leak; a corroded or damaged hood cannot draw as it should; a worn fan moves less air; a duct dented or partly blocked restricts the flow. These are physical faults that undermine the extraction, and they are often best identified by inspecting the system's condition directly rather than inferred from a reading alone. The inspection catches the causes; the measurements catch the effects.
There is also the matter of integrity and reliability over time. A reading might be acceptable today, but if the inspection reveals corrosion eating into a duct, a fan showing significant wear, or joints working loose, the system's future performance is in doubt even if its current numbers are fine. So the inspection assesses not just whether the system works now but whether it is physically sound - which speaks to whether it will keep working. This is why condition matters as much as the numbers: a system in poor physical condition is a system with a problem, whether or not that problem has fully shown up in the readings yet. The inspection sees the state of the system, which the numbers only partly reveal.
How it works with the measurements
The visual and structural inspection and the performance measurements are two halves of one judgement about the system, and they work together. The measurements quantify what the system is achieving - the airflows, the capture velocities, the pressures. The inspection establishes the physical condition behind those figures - whether the system is sound, damaged, worn or deteriorating. Neither alone is the full examination: numbers without condition miss the physical state that produces and will change them; condition without numbers misses the actual performance being achieved. Put together, they let the examiner judge both how the system is performing and whether its physical state supports that performance continuing.
This combination is also what lets the examination explain its findings, not just report them. A low reading at a hood makes sense when the inspection has found a leaking duct or a corroded hood feeding it - the condition explains the number. And a physical fault found in the inspection can be understood in terms of its effect on the measured performance. So the inspection and the measurements inform each other, building a coherent picture of the system: what it is doing, why, and whether it is physically sound enough to keep doing it. That is why the visual and structural inspection is a core part of a thorough examination - it is half of how the system is actually judged.
The takeaway
An LEV examination is not just readings on a meter - it includes a thorough visual and structural inspection of the whole system, and that inspection is a core part of it. The inspection surveys the physical condition of every part: the hoods for damage and corrosion, the ductwork for leaks, dents and deposits, the fan for wear, the filters for their state, and the joints, panels and supports that hold the system together and make it sound.
It matters as much as the numbers because the physical condition determines whether the system can perform, and some problems are found by looking rather than measuring - a leak, a corroded hood, a worn fan. The inspection catches the causes while the measurements catch the effects, and together they let the examiner judge both how the system is performing and whether its physical state supports that continuing. Looking matters as much as measuring, which is why a thorough examination does both.
Questions
No. Alongside the performance measurements - airflows, capture velocities, pressures - it includes a thorough visual and structural inspection of the whole system's physical condition. The inspection is a core part of the examination in its own right, not a preliminary glance, and it finds problems the numbers alone would miss.
The physical condition of every part: the hoods for damage, distortion and corrosion; the ductwork for leaks, dents, crushing and internal deposits; the fan for wear and the state of its impeller and drive; the filters for their condition; and the joints, access panels, mountings and general soundness of the installation.
Because condition determines whether the system can perform, and some faults are found by looking, not measuring - a leaking duct, a corroded hood, a worn fan. The inspection catches the causes while the measurements catch the effects, and a system in poor condition has a problem whether or not it has fully shown in the numbers yet.
Yes. Corrosion eating into a duct, a fan showing significant wear, or joints working loose may not yet show fully in a snapshot reading, but they threaten the system's future performance. The inspection assesses whether the system is physically sound - which speaks to whether it will keep working, not just whether it works now.
As two halves of one judgement. The measurements quantify what the system achieves; the inspection establishes the physical condition behind those figures. Together they let the examiner judge both how the system is performing and whether its state supports that continuing - and each explains the other, so findings are understood, not just reported.
Not on its own. A reading acceptable today can sit on a system with corrosion, wear or loosening joints that put its future in doubt. That is why the inspection matters alongside the numbers - it sees the physical state that the readings only partly reveal, and that determines whether performance will hold.
Our thorough examination inspects the physical condition of your whole system - hoods, ductwork, fan and filters - alongside measuring its performance, because looking and measuring together are how a system is properly judged.