Phoenix Cleaning Company Call 07961 915018
LEV Testing in Harrow

LEV Testing · Harrow

LEV testing in Harrow.

From the polymer and rubber-moulding shops to the engineering and finishing units, Harrow workplaces raise fume, mist and dust that the law says must be controlled - and the control proven by a thorough examination and test.

HSG258 examinationMeasured airflow readingsReport & labelFully insured

Where fume and dust control sits in Harrow

Harrow keeps a working manufacturing base behind its suburban face, including polymer and rubber processing among the units on its industrial estates. Its estates take in rubber moulding, polymer, engineering and finishing units, and every one raises something a worker should not breathe - rubber-cure and process fume, weld fume, oil mist, solvent or dust.

Local exhaust ventilation is what captures it at source, and the law does not take the control on trust. Under COSHH the extraction has to be thoroughly examined and tested at least every 14 months, measured against how it is used - not just switched on and assumed to work.

The Harrow workplaces that need an LEV test

01

Precision engineering

CNC and manual machining raises oil mist and metal dust at the enclosure and bench that has to be captured at source.

02

Food and drink production

Flour, powders and steam need capture at the mixing and process points, from bakeries to production kitchens.

03

Woodworking and joinery

Saws, sanders and routers throw fine wood dust that has to be drawn off at the tool and the bench.

04

Welding and fabrication

Weld fume and grinding dust need capture at the arm and booth, wherever steel is fabricated.

05

Vehicle body and paint

Bodyshop spray booths and prep bays carry paint mist and solvent vapour that the extraction has to hold and clear.

06

Laboratory and clinical

Fume cupboards, safety cabinets and dental and salon extraction all count as LEV and all fall due on the same clock.

What we have tested around Harrow

Real jobs, described by sector and area - never by a client's name.

Rubber-moulding unit · Harrow area

A cure-fume extraction test

At a rubber-moulding and extrusion unit on an estate near Harrow, the extraction over the press and cure line had lost capture and cure fume was hanging in the shop. We measured capture at each hood, checked the ducting and the filter, and found a fan below duty dragging the run. We set out the remedial action, and re-tested to confirm the control before certifying.

Engineering unit · Harrow area

A weld-fume and mist extraction test

At an engineering unit on an estate near Harrow, the weld-fume arms and mist extraction over the machining had lost capture and the shop was hazing by mid-shift. We measured capture and face velocities at each point, checked the ducting and the filters, and reported what needed putting right so it held its spec on a re-test.

What a thorough examination and test measures in Harrow

01

Visual and structural

Condition of hoods, ducting, filters and fan - the damage, blockage and wear that quietly drops performance.

02

Quantitative performance

Measured capture and face velocities at the working points, plus transport velocity and static pressure through the system.

03

Benchmark to design

The readings assessed against how the LEV should perform to actually control the exposure - not just whether the fan turns.

04

Air sampling, where needed

Where the process warrants it, sampling to confirm the control is keeping the substance out of the breathing zone.

LEV extraction arm and capture hood tested in Harrow

Fourteen months, and whose name is on it

A thorough examination and test under COSHH is a real assessment, not a rubber stamp. It is a structured examination of the system's condition, measurement of its actual performance, and an assessment of those readings against how the system should perform to control the exposure. It follows the HSE's guidance, HSG258, and ends in a report and a label.

We test to the HSE's guidance, HSG258, and the job ends in a report and a label on the plant: what was measured, what passed, what needs putting right, and the date the next test falls due.

  • Visual and structural examination of hoods, ducting, filter and fan
  • Measured airflow, capture and face velocities at the working points
  • Static pressure and duct transport velocity readings recorded
  • Report against the benchmark, with a label and the next-due date

Examine, measure, report, label

1

Examine

We inspect the system's condition - hoods, ducting, filter and fan - and identify how it is meant to control each process.

2

Measure

We take the readings: capture and face velocities, duct transport velocity and static pressure at the key points.

3

Report

We assess the readings against the benchmark and set out clearly whether the system is controlling the exposure.

4

Label

The system is labelled with the test result and next-due date, and you get the report for your COSHH file.

Frequently asked questions

How often does LEV have to be tested?

At least every 14 months under COSHH Regulation 9 - and sooner for certain higher-risk processes. We set the right interval for what you run and put the next-due date on the label and the report.

What do we get at the end?

A thorough-examination-and-test report against HSG258, a pass/fail on each point with any remedials listed, and a dated label on the plant showing when the next test falls due.

What if a point fails?

We set out exactly what failed and why - often a single reading such as static pressure or capture velocity - so it can be put right, and we re-test to confirm the control before certifying.

Do you cover the the borough's industrial estates and the wider town?

Yes - the the borough's industrial estates and the town's units, and across Harrow and the wider Greater London.

Do you only test engineering extraction?

No - any LEV: welding fume arms, wood and grain dust systems, spray booths, mist extraction, fume cupboards, and dental and salon extraction all fall under the same duty and the same clock.

LEV testing in Harrow

In and around Harrow

Behind its suburban face Harrow keeps its polymer, rubber-moulding and engineering units on the borough's estates, working with cure fume, mist and dust. Every one carries a duty to control what its work throws off - and to prove it with a measured test.

20+ years of experience

We have carried out LEV thorough examination and testing to HSG258 since 2001, across Greater London and the UK. From a machine shop to a joinery, a spray booth or a lab fume cupboard, the job ends the same way: measured readings, a clear verdict, and a label whose next-due date you can rely on.

Book your Harrow LEV thorough examination

Tell us what you run and we will examine, measure, report and label it to HSG258 - across Greater London.